RE-2X(St)YSWAY Instrumentation Cable

1 - Conductor:Stranded electrolytic copper conductor (Class 2) (IEC 60228, EN 60228, DIN VDE 0295)
2 - Insulation:XLPE (BS EN 50290-2, VDE 0207 YI1), White; Number coded (BS 5308-2)
3 - Stranding:In layers
4 - Wrapping:Polyester tape
5 - Screen:Tinned copper earthing wire, Al/PET tape
6 - Inner Jacket:PVC inner jacket. RAL 9005 (Black)
7 - Armor:Galvanized steel wire armor, polyester tape
8 - Outer Jacket:UV resistant PVC outer jacket. RAL 9005 (Black)
Conductor
Diameter
Conductor Resistance
Ω/km
(20 °C)
Insulation
Resistance
(@500V DC)
MΩ/km
Mutual Capacitance

nF/km
Operating
Voltage

V DC
Test Voltage

(@ 1 minute)
V DC
0.50 mm²36.0Min. 1000Max. 250300/5002000
0.75 mm²24.5Min. 1000Max. 250300/5002000
1.00 mm²18.1Min. 1000Max. 250300/5002000
1.50 mm²12.1Min. 1000Max. 250300/5002000
2.50 mm²7.41Min. 1000Max. 250300/5002000
Manufacturing ReferanceFlame Retardancy Test
EN 50288-7
or
IEC 60502-1
IEC 60332-1-2
Bending RadiusTemperature Range
Operating
7.5xD mm-30°C ~ +90°C

RE-2X(St)YSWAY Steel Wire Armored Instrumentation Cable

ETK Kablo’s RE-2X(St)YSWAY instrumentation cable is engineered for secure signal transmission and high mechanical protection in harsh industrial environments. Designed for demanding process automation and control systems, this cable combines EMI shielding with robust steel wire armoring for maximum performance in chemically and mechanically challenging applications.

The cable’s overall foil screen (St) ensures excellent protection against electromagnetic interference (EMI), maintaining signal integrity over long distances in high-noise zones. Galvanized steel wire armor (SWA) enhances mechanical durability, making the RE-2X(St)YSWAY suitable for direct burial, outdoor installation, and cable tray routing in energy plants, oil and gas facilities, and chemical processing sites.

With a LSZH or PVC outer sheath option, this instrumentation cable is flame-retardant and safe for use in critical infrastructure. It is designed for fixed installations in both dry and humid conditions, indoors or outdoors, where reliability and protection are paramount.

The RE-2X(St)YSWAY supports low-voltage analog and digital signal transmission for monitoring, control, and data acquisition systems. It meets international standards including EN 50288-7 and IEC 60332-1, and is available in CPR-rated versions upon request.

Choose ETK Kablo’s RE-2X(St)YSWAY — the steel wire armored instrumentation cable trusted for EMI-shielded, mechanically protected signal control in mission-critical industrial networks.