By continuing to use the website, you will be agreed with ETK Kablo’s use of cookies, GDPR and other policies.
x

PD-APV

• In indoor installations.
• Telephone exchanges and subscriber distributions.
• Signal and data transmission.
1 - Conductor:Class 1 electrolytic solid copper (IEC 60228, DIN VDE 0295, EN 60228)
2 - Insulation:Color coded foam skin polyethylene cladded with solid polyethylene (TS EN 60708)
3 - Stranding:In layers up to 10 pairs, 20 pairs to 100 pairs consist of stranding of 10 pair groups wrapped with polypropylene identification tape
4 - Wrapping:A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically. (More than 10 pairs)
5 - Screen:Tinned copper earthing wire, Al/PET tape
6 - Outer Jacket:UV resistant PVC outer jacket. RAL 7035 (Grey)
Conductor
Diameter
Conductor Resistance
Ω/km
(20 °C)
Insulation
Resistance
(@500V DC)
MΩ/km
Mutual Capacitance

nF/km
Capacitance
Unbalance

pF/500 m
Test Voltage

(@ 1 minute)
V DC
0.40 mm146.650001204001000
0.50 mm93.050001204001000
0.60 mm64.650001104001000
0.65 mm60.050001104001000
0.80 mm37.050001004001000
0.90 mm28.850001004001000
Flame Retardancy Test
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
Part NumberPair CountConductor Diameter (mm)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.340.1.5.2.0040.0.000110,42,94,312100/500/1000
3.340.1.5.2.0040.0.000220,43,46,717100/500/1000
3.340.1.5.2.0040.0.000330,44,3924100/500/1000
3.340.1.5.2.0040.0.000440,44,311,426100/500/1000
3.340.1.5.2.0040.0.000550,44,613,831100/500/1000
3.340.1.5.2.0040.0.000660,45,316,136100/500/1000
3.340.1.5.2.0040.0.000770,45,418,541100/500/1000
3.340.1.5.2.0040.0.000880,45,520,944100/500/1000
3.340.1.5.2.0040.0.000990,45,723,348100/500/1000
3.340.1.5.2.0040.0.0010100,45,725,651100/500/1000
3.340.1.5.2.0040.0.0012120,46,230,459100/500/1000
3.340.1.5.2.0040.0.0014140,47,235,172100/500/1000
3.340.1.5.2.0040.0.0015150,46,637,569100/500/1000
3.340.1.5.2.0040.0.0016160,46,839,873100/500/1000
3.340.1.5.2.0040.0.0020200,47,449,388100/500/1000
3.340.1.5.2.0040.0.0030300,49,873127100/500/1000
3.340.1.5.2.0040.0.0050500,411,9120,4196100/500/1000
3.340.1.5.2.0040.0.01001000,416,4243,5376100/500/1000

Part NumberPair CountConductor Diameter (mm)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.340.1.5.2.0050.0.000110,53.15,615100/500/1000
3.340.1.5.2.0050.0.000220,53.79,321100/500/1000
3.340.1.5.2.0050.0.000330,54,71329100/500/1000
3.340.1.5.2.0050.0.000440,54,916,735100/500/1000
3.340.1.5.2.0050.0.000550,5520,440100/500/1000
3.340.1.5.2.0050.0.000660,55,924,147100/500/1000
3.340.1.5.2.0050.0.000770,5627,853100/500/1000
3.340.1.5.2.0050.0.000880,56,131,557100/500/1000
3.340.1.5.2.0050.0.000990,56,235,262100/500/1000
3.340.1.5.2.0050.0.0010100,56,33968100/500/1000
3.340.1.5.2.0050.0.0012120,56,846,479100/500/1000
3.340.1.5.2.0050.0.0014140,57,253,889100/500/1000
3.340.1.5.2.0050.0.0015150,57,457,594100/500/1000
3.340.1.5.2.0050.0.0016160,57,661,299100/500/1000
3.340.1.5.2.0050.0.0020200,58,376121100/500/1000
3.340.1.5.2.0050.0.0030300,511,1113176100/500/1000
3.340.1.5.2.0050.0.0050500,513,8187282100/500/1000
3.340.1.5.2.0050.0.01001000,518,8379,4534100/500/1000
Bending RadiusTemperature Range
Operating
10xD mm-30°C ~ +70°C
Notes:
Reference Standard: TSEK 116