• In places where human life, valuable materials and equipments need to be protected. |
• In crowded indoor environments. |
• At instrumentation and control engineering. |
• At industrial electronics. |
• Computer and office devices. |
• Indoor communication systems. |
• Indoor sound systems. |
• Security and fire alarm systems. |
1 - Conductor | : | Class 1 electrolytic solid copper (IEC 60228, DIN VDE 0295, EN 60228) |
2 - Insulation | : | Polyethylene compound (VDE 0815, EN 50290-2-26) |
3 - Stranding | : | Two pairs are stranded into a star-quad, above two pairs are stranded together in layers |
4 - Wrapping | : | Polyester tape |
5 - Screen | : | Tinned copper earthing wire, Al/PET tape |
6 - Outer Jacket | : | UV resistant halogen-free outer jacket. RAL 6018 (Green) |
Conductor Diameter | Conductor Resistance Ω/km (20 °C) | Insulation Resistance (@500V DC) MΩ/km | Mutual Capacitance nF/km | Operating Voltage V DC | Test Voltage (@ 1 minute) V DC |
---|---|---|---|---|---|
0.60 mm | 130.0 | 5000 | 100 | 300 | 800 |
0.80 mm | 73.2 | 5000 | 100 | 300 | 800 |
1.00 mm | 44.6 | 5000 | 100 | 300 | 1000 |
1.50 mm² | 24.6 | 5000 | 100 | 300 | 1000 |
2.50 mm² | 15.1 | 5000 | 100 | 300 | 1000 |
Smoke Density Test | Corrosive Gas Test | Halogen-free Test | Flame Propagation Test | Flame Retardancy Test |
---|---|---|---|---|
IEC 61034-2, VDE 0482-1034-2, BS EN 61034-2 | IEC 60754-2, VDE 0482-267-2-3, BS EN 50267-2-3 | IEC 60754-1, VDE 0482-267-2-1, BS EN 50267-2-1 | IEC 60332-3-24, VDE 0482-332-3-24, EN 60332-2-24 | IEC 60332-1-2, VDE 0482-332-1-2, BS EN 60332-1-2 |
Bending Radius | Temperature Range Operating |
---|---|
10xD mm | -30°C ~ +70°C |