Mutual Capacitance | Propagation Velocity | Operating VoltageV | Test VoltageV | Characteristic Impedance |
---|---|---|---|---|
54±2 | 0,82 | 300/500 | 1200 | 75±3 |
Smoke Density Test | Corrosive Gas Test | Halogen-free Test | Flame Retardancy Test |
---|---|---|---|
IEC 61034-2 VDE 0482-1034-2 EN 61034-2 | IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3 | IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1 | IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 |
Part Number | Conductor Count | Conductor Diameter (mm²) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) |
---|---|---|---|---|---|---|
3.741.0.0.1.0100.0.0200 | 2 | 0,22 | 6,2 | 11,8 | 38 | 100 |
3.741.0.0.1.0100.0.0400 | 4 | 0,22 | 6,8 | 16 | 46 | 100 |
3.741.0.0.1.0100.0.0800 | 8 | 0,22 | 7,5 | 24,4 | 62 | 100 |
3.741.0.0.1.0100.0.1200 | 12 | 0,22 | 7,5 | 32,9 | 75 | 100 |
3.741.0.0.1.0100.0.1600 | 16 | 0,22 | 8,1 | 41,3 | 90 | 100 |
Part Number | Conductor Count | Conductor Diameter (mm²) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) |
---|---|---|---|---|---|---|
3.741.0.0.1.0500.0.0200 | - | 0,22 | 6,8 | 16,3 | 46,9 | 100 |
3.741.0.0.1.0500.0.0400 | - | 0,22 | 7,7 | 25 | 62,4 | 100 |
Part Number | Conductor Count | Conductor Diameter (mm²) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) |
---|---|---|---|---|---|---|
3.741.0.0.2.0100.0.0200 | 2 | 0,22 | 6,2 | 11,8 | 45 | 100 |
3.741.0.0.2.0100.0.0400 | 4 | 0,22 | 6,8 | 16 | 53 | 100 |
3.741.0.0.2.0100.0.0800 | 8 | 0,22 | 7,5 | 24,4 | 71 | 100 |
3.741.0.0.2.0100.0.1200 | 12 | 0,22 | 7,5 | 32,9 | 84 | 100 |
3.741.0.0.2.0100.0.1600 | 16 | 0,22 | 8,1 | 41,3 | 99 | 100 |
Part Number | Conductor Count | Conductor Diameter (mm²) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) |
---|---|---|---|---|---|---|
3.741.0.0.2.0500.0.0200 | - | 0,22 | 6,8 | 16,3 | 54,9 | 100 |
3.741.0.0.2.0500.0.0400 | - | 0,22 | 7,7 | 25 | 71,5 | 100 |
Part Number | Conductor Count | Conductor Diameter (mm²) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) |
---|---|---|---|---|---|---|
3.741.0.0.3.0100.0.0200 | 2 | 0,22 | 6,2 | 11,8 | 45 | 100 |
3.741.0.0.3.0100.0.0400 | 4 | 0,22 | 6,8 | 16 | 54 | 100 |
3.741.0.0.3.0100.0.0800 | 8 | 0,22 | 7,5 | 24,4 | 71 | 100 |
3.741.0.0.3.0100.0.1200 | 12 | 0,22 | 7,5 | 32,9 | 84 | 100 |
3.741.0.0.3.0100.0.1600 | 16 | 0,22 | 8,1 | 41,3 | 100 | 100 |
Bending Radius | Temperature Range Operating |
---|---|
15xD mm | -30°C~+70°C |