By continuing to use the website, you will be agreed with ETK Kablo’s use of cookies, GDPR and other policies.
x

LIH(St)H-TP (FE180 / PH120)

» Signal transmission.
» At instrumentation and control engineering.
» At industrial electronics.
» Computer and office devices.
» Indoor communication systems.
» Indoor sound systems.
» Security and fire alarm systems.
» In places where human life, valuable materials and equipments need to be protected.
1 - Conductor : Stranded electrolytic copper conductor (Class 5) (IEC 60228, EN 60228, DIN VDE 0295)
2 - Insulation : Cross-linked polymer compound in ceramic form (DIN 47100)
3 - Stranding : Insulations are stranded into pairs and all pairs are stranded together.
4 - Wrapping : Polyester tape, glass yarn tape
5 - Screen : Tinned copper earthing wire, Al/PET tape
6 - Outer Jacket : UV resistant halogen-free outer jacket. RAL 2008 (Orange)
Conductor
Diameter
Conductor Resistance
Ω/km (20 °C)
Insulation Resistance
M Ω/km (500 V DC)
Mutual Capacitance
nF/km (800 Hz)
Operating Voltage
V DC

Test Voltage
V
(DC, 1 minute)

0.50 mm²39201203002000
0.75 mm²26201203002000
1.00 mm²19.5201303002000
1.5 mm²13.3201403002000
2.5 mm²7.98201503002000
Smoke Density TestCorrosive Gas TestHalogen-free TestFlame Retardancy TestFlame Propagation Test
IEC 61034-2,
VDE 0482-1034-2,
BS EN 61034-2
IEC 60754-2,
VDE 0482-267-2-3,
BS EN 50267-2-3
IEC 60754-1,
VDE 0482-267-2-1,
EN 50267-2-1,
BS EN 50267-2-1
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
IEC 60332-3-24,
VDE 0482-332-3-24,
BS EN 60332-3-24


Circuit Integrity Test
(FE180)
Circuit Integrity with Shock Test
(PH120)
IEC 60331-23EN 50200, VDE 0482-200, BS EN 50200
Part NumberPair CountConductor Diameter (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.546.2.4.3.0050.0.000110,55,51142100/500/1000
3.546.2.4.3.0050.0.000220,57,319,968100/500/1000
3.546.2.4.3.0050.0.000330,58,428,790100/500/1000
3.546.2.4.3.0050.0.000440,510,137,6120100/500/1000
3.546.2.4.3.0050.0.000550,510,646,4136100/500/1000
3.546.2.4.3.0050.0.000660,511,255,2157100/500/1000
3.546.2.4.3.0050.0.000770,512,264,1180100/500/1000
3.546.2.4.3.0050.0.000880,512,672,9197100/500/1000
3.546.2.4.3.0050.0.000990,513,381,8219100/500/1000
3.546.2.4.3.0050.0.0010100,513,790,6230100/500/1000


Part NumberPair CountConductor Diameter (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.546.2.4.3.0075.0.000110,755,917,751100/500/1000
3.546.2.4.3.0075.0.000220,757,93184100/500/1000
3.546.2.4.3.0075.0.000330,759,144,2112100/500/1000
3.546.2.4.3.0075.0.000440,751157,5148100/500/1000
3.546.2.4.3.0075.0.000550,7511,570,8170100/500/1000
3.546.2.4.3.0075.0.000660,7512,284196100/500/1000
3.546.2.4.3.0075.0.000770,7513,297,3225100/500/1000
3.546.2.4.3.0075.0.000880,7513,7110,6248100/500/1000
3.546.2.4.3.0075.0.000990,7514,5123,9275100/500/1000
3.546.2.4.3.0075.0.0010100,7515,1137,1299100/500/1000


Part NumberPair CountConductor Diameter (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.546.2.4.3.0100.0.0001116,22157100/500/1000
3.546.2.4.3.0100.0.0002218,337,695100/500/1000
3.546.2.4.3.0100.0.0003319,654,2127100/500/1000
3.546.2.4.3.0100.0.00044111,770,8168100/500/1000
3.546.2.4.3.0100.0.00055112,287,4194100/500/1000
3.546.2.4.3.0100.0.00066112,9103,9225100/500/1000
3.546.2.4.3.0100.0.00077114120,5259100/500/1000
3.546.2.4.3.0100.0.00088114,6137,1286100/500/1000
3.546.2.4.3.0100.0.00099115,4153,7318100/500/1000
3.546.2.4.3.0100.0.001010116,1170,3346100/500/1000


Part NumberPair CountConductor Diameter (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.546.2.4.3.0150.0.000111,57,130,376100/500/1000
3.546.2.4.3.0150.0.000221,59,356,1122100/500/1000
3.546.2.4.3.0150.0.000331,510,782167100/500/1000
3.546.2.4.3.0150.0.000441,513,1107,8221100/500/1000
3.546.2.4.3.0150.0.000551,513,6133,6258100/500/1000
3.546.2.4.3.0150.0.000661,514,5159,5299100/500/1000
3.546.2.4.3.0150.0.000771,515,8185,3345100/500/1000
3.546.2.4.3.0150.0.000881,516,4211,2383100/500/1000
3.546.2.4.3.0150.0.000991,517,3237426100/500/1000
3.546.2.4.3.0150.0.0010101,518,1262,9465100/500/1000


Part NumberPair CountConductor Diameter (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.546.2.4.3.0250.0.000112,58,347,5104100/500/1000
3.546.2.4.3.0250.0.000222,51190,6175100/500/1000
3.546.2.4.3.0250.0.000332,512,8133,6242100/500/1000
3.546.2.4.3.0250.0.000442,515,6176,7318100/500/1000
3.546.2.4.3.0250.0.000552,516,4219,8380100/500/1000
Bending RadiusTemperature Range
Operating
10xD mm-40°C~+70°C
Notes:
Reference Standard: DIN VDE 0812