By continuing to use the website, you will be agreed with ETK Kablo’s use of cookies, GDPR and other policies.
x

J-Y(St)Y Lg

• At instrumentation and control engineering.
• At industrial electronics.
• Computer and office devices.
• Indoor communication systems.
• Indoor sound systems.
• Security and fire alarm systems.
1 - Conductor:Class 1 electrolytic solid copper (IEC 60228, DIN VDE 0295, EN 60228)
2 - Insulation:PVC compound (VDE 0815, EN 50290-2-21)
3 - Stranding:Two pairs are stranded into a star-quad, above two pairs are stranded together in layers
4 - Wrapping:Polyester tape
5 - Screen:Tinned copper earthing wire, Al/PET tape
6 - Outer Jacket:UV resistant PVC outer jacket. RAL 3000 (Red)
Conductor
Diameter
Conductor Resistance
Ω/km
(20 °C)
Insulation
Resistance
(@500V DC)
MΩ/km
Mutual Capacitance

nF/km
Operating
Voltage

V DC
Test Voltage

(@ 1 minute)
V DC
0.60 mm130.0100100300800
0.80 mm73.2100100300800
1.00 mm44.61001003001000
1.50 mm²24.61001003001000
2.50 mm²15.11001003001000
Flame Retardancy Test
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
Part
Number
Pair
Count
Conductor Diameter
(mm)
Cross Section
(mm²)
Approx. Cable Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
Packing Lengths
(m)
3.640.1.2.2.0060.0.000110,6-4,17,221100/500/1000
3.640.1.2.2.0060.0.000220,6-4,712,531100/500/1000
3.640.1.2.2.0060.0.000330,6-6,117,845100/500/1000
3.640.1.2.2.0060.0.000440,6-7,223,157100/500/1000
3.640.1.2.2.0060.0.000550,6-7,528,467100/500/1000
3.640.1.2.2.0060.0.000660,6-9,133,782100/500/1000
3.640.1.2.2.0060.0.000880,6-9,344,398100/500/1000
3.640.1.2.2.0060.0.0010100,6-9,754,9116100/500/1000
3.640.1.2.2.0060.0.0012120,6-10,465,6134100/500/1000
3.640.1.2.2.0060.0.0014140,6-11,376,2157100/500/1000
3.640.1.2.2.0060.0.0016160,6-11,986,8175100/500/1000
3.640.1.2.2.0060.0.0020200,6-13,3108211100/500/1000
3.640.1.2.2.0060.0.0024240,6-14,3129,2251100/500/1000
3.640.1.2.2.0060.0.0025250,6-14,5134,5260100/500/1000
3.640.1.2.2.0060.0.0030300,6-18,8161,1329100/500/1000
3.640.1.2.2.0060.0.0040400,6-20,8214,1415100/500/1000
3.640.1.2.2.0060.0.0050500,6-23267,2502100/500/1000
3.640.1.2.2.0060.0.0060600,6-25,1320,2601100/500/1000
3.640.1.2.2.0060.0.0080800,6-28,1426,3768100/500/1000
3.640.1.2.2.0060.0.01001000,6-32,1532,4956100/500/1000


Part
Number
Pair
Count
Conductor Diameter
(mm)
Cross Section
(mm²)
Approx. Cable Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
Packing Lengths
(m)
3.640.1.2.2.0080.0.000110,8-4,611,328100/500/1000
3.640.1.2.2.0080.0.000220,8-5,320,743100/500/1000
3.640.1.2.2.0080.0.000330,8-6,930,263100/500/1000
3.640.1.2.2.0080.0.000440,8-8,139,680100/500/1000
3.640.1.2.2.0080.0.000550,8-8,649,196100/500/1000
3.640.1.2.2.0080.0.000660,8-10,458,5116100/500/1000
3.640.1.2.2.0080.0.000880,8-10,777,3141100/500/1000
3.640.1.2.2.0080.0.0010100,8-11,196,2169100/500/1000
3.640.1.2.2.0080.0.0012120,8-11,9115,1197100/500/1000
3.640.1.2.2.0080.0.0014140,8-12,8133,9228100/500/1000
3.640.1.2.2.0080.0.0016160,8-13,5152,8255100/500/1000
3.640.1.2.2.0080.0.0020200,8-15,2190,5311100/500/1000
3.640.1.2.2.0080.0.0024240,8-16,2228,3370100/500/1000
3.640.1.2.2.0080.0.0025250,8-16,5237,7384100/500/1000
3.640.1.2.2.0080.0.0030300,8-21,3284,8470100/500/1000
3.640.1.2.2.0080.0.0040400,8-23,8379,2613100/500/1000
3.640.1.2.2.0080.0.0050500,8-26,4473,5748100/500/1000
3.640.1.2.2.0080.0.0060600,8-28,8567,8896100/500/1000
3.640.1.2.2.0080.0.0080800,8-32,3756,41156100/500/1000
3.640.1.2.2.0080.0.01001000,8-36,8945,11423100/500/1000


Part
Number
Pair
Count
Conductor Diameter
(mm)
Cross Section
(mm²)
Approx. Cable Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
Packing Lengths
(m)
3.640.1.2.2.0100.0.000111-5,519,641100/500/1000
3.640.1.2.2.0100.0.000221-6,334,464100/500/1000
3.640.1.2.2.0100.0.000331-8,149,590100/500/1000
3.640.1.2.2.0100.0.000441-9,664,3115100/500/1000
3.640.1.2.2.0100.0.000551-10,179,2137100/500/1000
3.640.1.2.2.0100.0.000661-12,394,1166100/500/1000
3.640.1.2.2.0100.0.000881-12,7123,9207100/500/1000
3.640.1.2.2.0100.0.0010101-13,1153,6243100/500/1000
3.640.1.2.2.0100.0.0012121-14,1183,4286100/500/1000
3.640.1.2.2.0100.0.0014141-15,2213,1331100/500/1000
3.640.1.2.2.0100.0.0016161-16,1242,9372100/500/1000
3.640.1.2.2.0100.0.0020201-18302,4454100/500/1000


Part
Number
Pair
Count
Conductor Diameter
(mm)
Cross Section
(mm²)
Approx. Cable Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
Packing Lengths
(m)
3.640.1.2.2.0150.0.00011-1,56,832,263100/500/1000
3.640.1.2.2.0150.0.00022-1,57,859,6102100/500/1000
3.640.1.2.2.0150.0.00033-1,510,287,4147100/500/1000
3.640.1.2.2.0150.0.00044-1,512,5114,9197100/500/1000
3.640.1.2.2.0150.0.00055-1,513,1142,4233100/500/1000
3.640.1.2.2.0150.0.00066-1,516,2170290100/500/1000
3.640.1.2.2.0150.0.00088-1,516,9225368100/500/1000
3.640.1.2.2.0150.0.001010-1,517,4280438100/500/1000


Part
Number
Pair
Count
Conductor Diameter
(mm)
Cross Section
(mm²)
Approx. Cable Diameter
(mm)
Copper Weight
(kg/km)
Approx. Weight
(kg/km)
Packing Lengths
(m)
3.640.1.2.2.0250.0.00011-2,57,849,688100/500/1000
3.640.1.2.2.0250.0.00022-2,5994,4148100/500/1000
3.640.1.2.2.0250.0.00033-2,511,9140215100/500/1000
3.640.1.2.2.0250.0.00044-2,514,5185283100/500/1000
3.640.1.2.2.0250.0.00055-2,515,1230,1339100/500/1000
3.640.1.2.2.0250.0.00066-2,518,9275,1419100/500/1000
3.640.1.2.2.0250.0.00088-2,519,7365,2537100/500/1000
3.640.1.2.2.0250.0.001010-2,520,3455,3647100/500/1000
Bending RadiusTemperature Range
Operating
10xD mm-30°C ~ +70°C
Notes:
Reference Standard: DIN VDE 0815, TSEK