{"id":5406,"date":"2025-10-07T21:35:10","date_gmt":"2025-10-07T18:35:10","guid":{"rendered":"https:\/\/www.etkkablo.com\/en\/?p=5406"},"modified":"2026-10-09T15:32:18","modified_gmt":"2026-10-09T12:32:18","slug":"what-are-control-cables","status":"publish","type":"post","link":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/","title":{"rendered":"What Are Control Cables? Types, Uses &amp; Selection Guide"},"content":{"rendered":"\n<p id=\"wd-2f601541\" class=\"wp-block-wd-paragraph\"><strong>What are control cables?<\/strong> Control cables are multi-core electrical cables used to transmit commands, switching signals, control functions and, in suitable circuits, low-voltage electrical energy between industrial equipment. They commonly connect control panels, PLC systems, relays, contactors, actuators, motors, valves and other automation devices.<\/p>\n\n\n\n<p id=\"wd-b18c825c\" class=\"wp-block-wd-paragraph\">However, control cable is not one fixed construction. Some designs use PVC insulation and sheath, while others use halogen-free materials. In addition, engineers can choose screened or unscreened versions, different conductor sizes, different core-identification systems and different voltage ratings.<\/p>\n\n\n\n<p id=\"wd-119eb092\" class=\"wp-block-wd-paragraph\">For example, YSLY is an unscreened flexible PVC control-cable family. YSLCY adds a tinned-copper braid screen. YSLYCY adds both screening and an additional inner sheath. Meanwhile, HSLH and HSLCH families use halogen-free materials for projects that require a different fire and material strategy.<\/p>\n\n\n\n<p id=\"wd-d83423b5\" class=\"wp-block-wd-paragraph\">Therefore, selecting the correct control cable requires more than choosing a familiar product code. Engineers should define the electrical circuit, conductor size, core count, voltage rating, electromagnetic environment, installation method, sheath material and fire requirements.<\/p>\n\n\n\n<p id=\"wd-aaaf42c0\" class=\"wp-block-wd-paragraph\">ETK Kablo manufactures a broad <a href=\"\/en\/product-cat\/control-cables\/\">industrial automation cable portfolio<\/a> for machinery, control panels, production systems, HVAC, building automation and other control applications.<\/p>\n\n\n\n<p id=\"wd-54ee2d59\" class=\"wp-block-wd-paragraph\"><strong>Quick answer:<\/strong> Control cables connect control equipment and field devices in automation systems. Choose an unscreened design where electromagnetic interference is limited. Select a screened construction when the route requires additional EMI protection. Then specify PVC or halogen-free materials, conductor size, voltage rating and core identification according to the actual circuit and installation environment.<\/p>\n\n\n\n<h2 id=\"wd-1c77c457\" class=\"wp-block-wd-title title\">What Are Control Cables Used For?<\/h2>\n\n\n\n<p id=\"wd-0d5283a0\" class=\"wp-block-wd-paragraph\"><strong>What are control cables<\/strong> used for in practice? Their main role is to connect devices that command, monitor or coordinate industrial and building systems.<\/p>\n\n\n\n<p id=\"wd-5ec3ef9b\" class=\"wp-block-wd-paragraph\">Typical circuits include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PLC outputs<\/li>\n\n\n\n<li>Relay circuits<\/li>\n\n\n\n<li>Contactor control<\/li>\n\n\n\n<li>Motor-start commands<\/li>\n\n\n\n<li>Valve and actuator control<\/li>\n\n\n\n<li>Machine interlocks<\/li>\n\n\n\n<li>Limit switches<\/li>\n\n\n\n<li>Control-panel field connections<\/li>\n\n\n\n<li>HVAC controls<\/li>\n\n\n\n<li>Conveyor systems<\/li>\n\n\n\n<li>Production-line controls<\/li>\n\n\n\n<li>Building automation<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-9c5c3f53\" class=\"wp-block-wd-paragraph\">As a result, control cables appear in almost every automated industrial facility.<\/p>\n\n\n\n<p id=\"wd-1f7dd4b8\" class=\"wp-block-wd-paragraph\">Nevertheless, the cable does not define the control protocol by itself. The connected equipment and circuit design determine what signal or electrical function travels through each core.<\/p>\n\n\n\n<h2 id=\"wd-60c8d131\" class=\"wp-block-wd-title title\">What Are Control Cables Made Of?<\/h2>\n\n\n\n<p id=\"wd-2b5308d6\" class=\"wp-block-wd-paragraph\">A typical flexible control cable contains several insulated copper conductors assembled into one multi-core cable.<\/p>\n\n\n\n<p id=\"wd-37a06e0d\" class=\"wp-block-wd-paragraph\">The construction can include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Class 5 stranded copper conductors<\/li>\n\n\n\n<li>PVC or halogen-free insulation<\/li>\n\n\n\n<li>Number-coded or color-coded cores<\/li>\n\n\n\n<li>Green-yellow protective conductor where required<\/li>\n\n\n\n<li>Polyester tape or another separator<\/li>\n\n\n\n<li>Tinned-copper braid screen<\/li>\n\n\n\n<li>Al\/PET foil in selected screened designs<\/li>\n\n\n\n<li>Inner sheath in specific constructions<\/li>\n\n\n\n<li>PVC or halogen-free outer sheath<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-994916ef\" class=\"wp-block-wd-paragraph\">However, not every control cable contains every layer. The project requirements determine the final construction.<\/p>\n\n\n\n<h2 id=\"wd-e0de4fe2\" class=\"wp-block-wd-title title\">Control Cable Construction at a Glance<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Component<\/th><th>Typical Option<\/th><th>Main Function<\/th><\/tr><\/thead><tbody><tr><td>Conductor<\/td><td>Class 5 stranded copper<\/td><td>Electrical conduction and installation flexibility<\/td><\/tr><tr><td>Insulation<\/td><td>PVC or halogen-free compound<\/td><td>Electrical separation between cores<\/td><\/tr><tr><td>Core identification<\/td><td>Number or color coding<\/td><td>Installation and circuit identification<\/td><\/tr><tr><td>Protective conductor<\/td><td>Green-yellow core where specified<\/td><td>Protective-earth connection<\/td><\/tr><tr><td>Screen<\/td><td>Tinned-copper braid and\/or foil<\/td><td>EMI control<\/td><\/tr><tr><td>Inner sheath<\/td><td>Product-dependent<\/td><td>Additional structural layer<\/td><\/tr><tr><td>Outer sheath<\/td><td>PVC or halogen-free compound<\/td><td>Mechanical and environmental protection<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p id=\"wd-da80c4b9\" class=\"wp-block-wd-paragraph\">Therefore, product names that look similar can hide meaningful structural differences.<\/p>\n\n\n\n<h2 id=\"wd-b7ba014a\" class=\"wp-block-wd-title title\">Class 5 Copper Conductors<\/h2>\n\n\n\n<p id=\"wd-f04b63f1\" class=\"wp-block-wd-paragraph\">Many ETK flexible control-cable families use Class 5 stranded copper conductors.<\/p>\n\n\n\n<p id=\"wd-28cf7f04\" class=\"wp-block-wd-paragraph\">IEC 60228 defines conductor classes and resistance requirements for insulated cable conductors. The current <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71891\" target=\"_blank\" rel=\"noreferrer noopener\">IEC 60228:2023 standard<\/a> includes requirements for flexible copper conductors such as Class 5.<\/p>\n\n\n\n<p id=\"wd-7d724a34\" class=\"wp-block-wd-paragraph\">Class 5 construction uses multiple fine copper wires rather than one solid conductor. Therefore, it provides greater installation flexibility than a solid conductor of the same nominal cross-section.<\/p>\n\n\n\n<p id=\"wd-c0069e19\" class=\"wp-block-wd-paragraph\">However, an important distinction is necessary:<\/p>\n\n\n\n<p id=\"wd-4c862601\" class=\"wp-block-wd-paragraph\"><strong>Class 5 flexible conductor does not automatically mean continuous-flex cable.<\/strong><\/p>\n\n\n\n<p id=\"wd-df1d19ed\" class=\"wp-block-wd-paragraph\">A cable can use Class 5 conductors and still be intended mainly for fixed installation or occasional movement. Continuous movement in drag chains, robotics or repeated torsion requires a cable specifically designed and tested for that duty.<\/p>\n\n\n\n<h2 id=\"wd-8becb930\" class=\"wp-block-wd-title title\">Flexible Does Not Mean Drag-Chain Rated<\/h2>\n\n\n\n<p id=\"wd-f94eca55\" class=\"wp-block-wd-paragraph\">This distinction prevents a common specification mistake.<\/p>\n\n\n\n<p id=\"wd-cac1df7f\" class=\"wp-block-wd-paragraph\">A standard flexible industrial control cable can simplify routing inside machinery and panels. It can also tolerate movement during installation.<\/p>\n\n\n\n<p id=\"wd-d0527dd4\" class=\"wp-block-wd-paragraph\">However, repeated dynamic movement creates a different mechanical load.<\/p>\n\n\n\n<p id=\"wd-a9913212\" class=\"wp-block-wd-paragraph\">Applications such as these need dedicated evaluation:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Drag chains<\/li>\n\n\n\n<li>Robotics<\/li>\n\n\n\n<li>Repeated bending<\/li>\n\n\n\n<li>Torsional movement<\/li>\n\n\n\n<li>High-cycle machine axes<\/li>\n\n\n\n<li>Moving gantries<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-e248dcb9\" class=\"wp-block-wd-paragraph\">Therefore, buyers should never infer continuous-flex capability from the word \u201cflexible\u201d alone.<\/p>\n\n\n\n<h2 id=\"wd-0f4ff884\" class=\"wp-block-wd-title title\">YSLY Control Cable<\/h2>\n\n\n\n<p id=\"wd-c572c4ec\" class=\"wp-block-wd-paragraph\">YSLY represents one of the most common flexible PVC control-cable families.<\/p>\n\n\n\n<p id=\"wd-7ddaee1e\" class=\"wp-block-wd-paragraph\">A typical construction uses:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Class 5 stranded copper conductors<\/li>\n\n\n\n<li>PVC conductor insulation<\/li>\n\n\n\n<li>Layer stranding<\/li>\n\n\n\n<li>PVC outer sheath<\/li>\n\n\n\n<li>No metallic screen<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-d5b37857\" class=\"wp-block-wd-paragraph\">As a result, YSLY provides a relatively simple and flexible construction for control circuits where strong electromagnetic interference is not a major concern.<\/p>\n\n\n\n<p id=\"wd-cee8eec4\" class=\"wp-block-wd-paragraph\">Typical applications include machine wiring, control cabinets, production lines, HVAC systems and conveyor equipment.<\/p>\n\n\n\n<h2 id=\"wd-0d3f1828\" class=\"wp-block-wd-title title\">YSLY-JZ Control Cable<\/h2>\n\n\n\n<p id=\"wd-48785a4c\" class=\"wp-block-wd-paragraph\">YSLY-JZ combines the YSLY construction with a particular core-identification arrangement.<\/p>\n\n\n\n<p id=\"wd-904b5f52\" class=\"wp-block-wd-paragraph\">ETK Kablo&#8217;s <a href=\"\/en\/product\/ysly-jz-control-cable\/\">YSLY-JZ product<\/a> uses Class 5 stranded copper conductors, PVC insulation and a PVC outer sheath. The cores are black with white numbers and include a green-yellow protective conductor.<\/p>\n\n\n\n<p id=\"wd-4af33150\" class=\"wp-block-wd-paragraph\">ETK&#8217;s current standard YSLY-JZ range includes conductor sizes from 0.50 mm\u00b2 to 16 mm\u00b2 and a published operating-voltage value of 300\/500 V for these variants.<\/p>\n\n\n\n<p id=\"wd-17c356a9\" class=\"wp-block-wd-paragraph\">However, buyers should always use the datasheet for the exact ordered size and construction.<\/p>\n\n\n\n<h2 id=\"wd-53e061a6\" class=\"wp-block-wd-title title\">JZ, OZ, JB and OB: What Do the Codes Mean?<\/h2>\n\n\n\n<p id=\"wd-cb411a2f\" class=\"wp-block-wd-paragraph\">Control-cable designations often include additional letters that describe core identification and the presence of a protective conductor.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Code<\/th><th>Typical Meaning<\/th><\/tr><\/thead><tbody><tr><td>JZ<\/td><td>Number-coded cores with green-yellow protective conductor<\/td><\/tr><tr><td>OZ<\/td><td>Number-coded cores without green-yellow protective conductor<\/td><\/tr><tr><td>JB<\/td><td>Color-coded cores with green-yellow protective conductor<\/td><\/tr><tr><td>OB<\/td><td>Color-coded cores without green-yellow protective conductor<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p id=\"wd-d316a5d6\" class=\"wp-block-wd-paragraph\">This identification system helps installation teams select the correct cable for panel and machine wiring.<\/p>\n\n\n\n<p id=\"wd-654d6865\" class=\"wp-block-wd-paragraph\">Nevertheless, buyers should verify the manufacturer&#8217;s actual product documentation. Commercial naming conventions can vary across markets and product families.<\/p>\n\n\n\n<h2 id=\"wd-ab9a4738\" class=\"wp-block-wd-title title\">Screened vs Unscreened Control Cable<\/h2>\n\n\n\n<p id=\"wd-96a9050c\" class=\"wp-block-wd-paragraph\">One of the most important decisions involves electromagnetic screening.<\/p>\n\n\n\n<p id=\"wd-d0495b29\" class=\"wp-block-wd-paragraph\">An unscreened cable relies on its basic conductor geometry and installation environment. Therefore, it can provide an efficient solution where EMI levels remain controlled.<\/p>\n\n\n\n<p id=\"wd-ab0f2409\" class=\"wp-block-wd-paragraph\">A screened construction adds a conductive layer around the cable core. A tinned-copper braid is common in flexible industrial control cables.<\/p>\n\n\n\n<p id=\"wd-13f34e63\" class=\"wp-block-wd-paragraph\">The screen can help reduce the influence of external electromagnetic fields on sensitive circuits.<\/p>\n\n\n\n<p id=\"wd-11490c4a\" class=\"wp-block-wd-paragraph\">However, more screening does not automatically create a better cable. Screening increases material, diameter, weight and termination requirements.<\/p>\n\n\n\n<p id=\"wd-aeb4c7c0\" class=\"wp-block-wd-paragraph\">Therefore, the route should justify the screen.<\/p>\n\n\n\n<h2 id=\"wd-35fa89c0\" class=\"wp-block-wd-title title\">When Should You Use a Screened Control Cable?<\/h2>\n\n\n\n<p id=\"wd-f11c8c26\" class=\"wp-block-wd-paragraph\">Screened designs become more relevant where control circuits run near strong electrical-noise sources.<\/p>\n\n\n\n<p id=\"wd-41080b61\" class=\"wp-block-wd-paragraph\">Examples include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Variable-frequency drives<\/li>\n\n\n\n<li>Large electric motors<\/li>\n\n\n\n<li>Transformers<\/li>\n\n\n\n<li>Switchgear<\/li>\n\n\n\n<li>High-current power cables<\/li>\n\n\n\n<li>Power converters<\/li>\n\n\n\n<li>Dense industrial electrical panels<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-479288af\" class=\"wp-block-wd-paragraph\">In these environments, a copper braid can improve electromagnetic compatibility.<\/p>\n\n\n\n<p id=\"wd-0406b28b\" class=\"wp-block-wd-paragraph\">However, correct routing, separation and screen termination remain important. A screened cable alone cannot repair poor system design.<\/p>\n\n\n\n<h2 id=\"wd-f9c113c0\" class=\"wp-block-wd-title title\">YSLY vs YSLCY vs YSLYCY<\/h2>\n\n\n\n<p id=\"wd-0e61c98c\" class=\"wp-block-wd-paragraph\">These three families illustrate how one basic control-cable concept changes through screening and additional construction layers.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Feature<\/th><th>YSLY<\/th><th>YSLCY<\/th><th>YSLYCY<\/th><\/tr><\/thead><tbody><tr><td>Conductor<\/td><td>Class 5 copper<\/td><td>Class 5 copper<\/td><td>Class 5 copper<\/td><\/tr><tr><td>Insulation<\/td><td>PVC<\/td><td>PVC<\/td><td>PVC<\/td><\/tr><tr><td>Metallic screen<\/td><td>No<\/td><td>Tinned-copper braid<\/td><td>Tinned-copper braid<\/td><\/tr><tr><td>Inner sheath<\/td><td>No<\/td><td>No extruded inner sheath in the standard ETK construction<\/td><td>PVC inner sheath<\/td><\/tr><tr><td>Outer sheath<\/td><td>PVC<\/td><td>PVC<\/td><td>PVC<\/td><\/tr><tr><td>General selection direction<\/td><td>Low-EMI control<\/td><td>Screened control<\/td><td>Screened control with additional inner-sheath structure<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p id=\"wd-d7461171\" class=\"wp-block-wd-paragraph\">Therefore, the difference between YSLCY and YSLYCY is not simply screening. Both are screened. The additional inner sheath distinguishes YSLYCY from ETK&#8217;s standard YSLCY construction.<\/p>\n\n\n\n<p id=\"wd-88c3632f\" class=\"wp-block-wd-paragraph\">For a complete technical comparison, see our <a href=\"\/en\/blog\/ysly-vs-yslcy-vs-yslycy\/\">YSLY, YSLCY and YSLYCY comparison<\/a>.<\/p>\n\n\n\n<h2 id=\"wd-63c74759\" class=\"wp-block-wd-title title\">PVC Control Cables<\/h2>\n\n\n\n<p id=\"wd-5d665f9e\" class=\"wp-block-wd-paragraph\">PVC remains widely used in industrial control cabling.<\/p>\n\n\n\n<p id=\"wd-46d83cdd\" class=\"wp-block-wd-paragraph\">It can provide a practical combination of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Flexibility<\/li>\n\n\n\n<li>Mechanical durability<\/li>\n\n\n\n<li>Cost efficiency<\/li>\n\n\n\n<li>Processability<\/li>\n\n\n\n<li>Industrial installation convenience<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-e6229faa\" class=\"wp-block-wd-paragraph\">For this reason, YSLY and related families commonly use PVC insulation and sheath systems.<\/p>\n\n\n\n<p id=\"wd-7ff18ac9\" class=\"wp-block-wd-paragraph\">However, PVC does not suit every fire or material requirement.<\/p>\n\n\n\n<h2 id=\"wd-b0fe0960\" class=\"wp-block-wd-title title\">Halogen-Free Control Cables<\/h2>\n\n\n\n<p id=\"wd-fdfc2d85\" class=\"wp-block-wd-paragraph\">Projects that prioritize low-smoke and halogen-free materials can use HSLH or HSLCH-type constructions.<\/p>\n\n\n\n<p id=\"wd-82ee85ab\" class=\"wp-block-wd-paragraph\">In general terms, the halogen-free family replaces the PVC insulation and sheath approach with halogen-free compounds.<\/p>\n\n\n\n<p id=\"wd-420d7287\" class=\"wp-block-wd-paragraph\">Meanwhile, screened versions add electromagnetic protection where required.<\/p>\n\n\n\n<p id=\"wd-c0de4cd8\" class=\"wp-block-wd-paragraph\">However, halogen-free does not automatically mean fire-resistant. It also does not automatically define a specific CPR Euroclass.<\/p>\n\n\n\n<p id=\"wd-9328c4ed\" class=\"wp-block-wd-paragraph\">These are separate properties.<\/p>\n\n\n\n<p id=\"wd-425a8897\" class=\"wp-block-wd-paragraph\">For a broader material comparison, see our <a href=\"\/en\/blog\/lszh-vs-pvc-cable\/\">LSZH vs PVC cable guide<\/a>.<\/p>\n\n\n\n<h2 id=\"wd-6fdfa910\" class=\"wp-block-wd-title title\">Flame Retardant vs Fire Resistant<\/h2>\n\n\n\n<p id=\"wd-40444582\" class=\"wp-block-wd-paragraph\">Control-cable specifications often mix these two concepts.<\/p>\n\n\n\n<p id=\"wd-42660996\" class=\"wp-block-wd-paragraph\">A flame-retardant test evaluates how a cable behaves when exposed to flame and whether flame propagation remains within defined criteria.<\/p>\n\n\n\n<p id=\"wd-db8a5831\" class=\"wp-block-wd-paragraph\">Fire resistance addresses a different question: can the cable maintain its required electrical function during a specified fire test?<\/p>\n\n\n\n<p id=\"wd-fc5da58c\" class=\"wp-block-wd-paragraph\">Therefore, a cable that passes a flame-propagation test does not automatically provide fire-resistant circuit integrity.<\/p>\n\n\n\n<p id=\"wd-c250839e\" class=\"wp-block-wd-paragraph\">Likewise, LSZH material characteristics do not automatically create fire resistance.<\/p>\n\n\n\n<h2 id=\"wd-24b2610e\" class=\"wp-block-wd-title title\">Control Cable Voltage Ratings<\/h2>\n\n\n\n<p id=\"wd-88527cc9\" class=\"wp-block-wd-paragraph\">There is no single universal voltage rating for all control cables.<\/p>\n\n\n\n<p id=\"wd-cbeadbf8\" class=\"wp-block-wd-paragraph\">ETK&#8217;s current product portfolio includes common control families at 300\/500 V as well as dedicated 450\/750 V constructions.<\/p>\n\n\n\n<p id=\"wd-0e21e438\" class=\"wp-block-wd-paragraph\">Therefore, engineers should select the voltage class from the actual circuit and the exact product datasheet.<\/p>\n\n\n\n<p id=\"wd-11e2e2f2\" class=\"wp-block-wd-paragraph\">Do not assume that two cables with similar names have identical voltage ratings.<\/p>\n\n\n\n<h2 id=\"wd-6b770643\" class=\"wp-block-wd-title title\">300\/500 V vs 450\/750 V Control Cable<\/h2>\n\n\n\n<p id=\"wd-cae0fe10\" class=\"wp-block-wd-paragraph\">The higher voltage designation does not automatically make a cable better for every application.<\/p>\n\n\n\n<p id=\"wd-b800fd00\" class=\"wp-block-wd-paragraph\">The correct choice depends on the electrical circuit and applicable installation rules.<\/p>\n\n\n\n<p id=\"wd-f951b830\" class=\"wp-block-wd-paragraph\">A 300\/500 V control cable can provide the appropriate solution for many automation circuits. Meanwhile, other machine or industrial systems may require a 450\/750 V product family.<\/p>\n\n\n\n<p id=\"wd-d7bd622f\" class=\"wp-block-wd-paragraph\">Therefore, voltage rating should form part of the original specification rather than an afterthought.<\/p>\n\n\n\n<h2 id=\"wd-ce55f01b\" class=\"wp-block-wd-title title\">What Conductor Size Should a Control Cable Use?<\/h2>\n\n\n\n<p id=\"wd-ec933c49\" class=\"wp-block-wd-paragraph\">Control-cable conductor sizes vary according to circuit function.<\/p>\n\n\n\n<p id=\"wd-e3e60cf4\" class=\"wp-block-wd-paragraph\">Common sizes include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>0.50 mm\u00b2<\/li>\n\n\n\n<li>0.75 mm\u00b2<\/li>\n\n\n\n<li>1.00 mm\u00b2<\/li>\n\n\n\n<li>1.50 mm\u00b2<\/li>\n\n\n\n<li>2.50 mm\u00b2<\/li>\n\n\n\n<li>4.00 mm\u00b2<\/li>\n\n\n\n<li>6.00 mm\u00b2<\/li>\n\n\n\n<li>Larger project-specific sizes<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-4dff97ee\" class=\"wp-block-wd-paragraph\">However, popularity should not determine conductor size.<\/p>\n\n\n\n<p id=\"wd-9df8d45e\" class=\"wp-block-wd-paragraph\">Engineers should consider:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Circuit current<\/li>\n\n\n\n<li>Route length<\/li>\n\n\n\n<li>Voltage drop<\/li>\n\n\n\n<li>Conductor resistance<\/li>\n\n\n\n<li>Protective-device requirements<\/li>\n\n\n\n<li>Terminal size<\/li>\n\n\n\n<li>Ambient temperature<\/li>\n\n\n\n<li>Installation conditions<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-6b0a93cc\" class=\"wp-block-wd-paragraph\">As a result, one machine can use several conductor sizes across different control circuits.<\/p>\n\n\n\n<h2 id=\"wd-2445f999\" class=\"wp-block-wd-title title\">How Many Cores Should a Control Cable Have?<\/h2>\n\n\n\n<p id=\"wd-4ac27eb9\" class=\"wp-block-wd-paragraph\">Control cables can contain a few cores or several dozen.<\/p>\n\n\n\n<p id=\"wd-df463ab1\" class=\"wp-block-wd-paragraph\">The required number depends on the automation architecture.<\/p>\n\n\n\n<p id=\"wd-4058e4c8\" class=\"wp-block-wd-paragraph\">For example, a simple actuator can need only a few connections. By contrast, a large field junction or machine interface can require many individual control circuits in one cable.<\/p>\n\n\n\n<p id=\"wd-12480444\" class=\"wp-block-wd-paragraph\">However, additional spare cores can also help future expansion.<\/p>\n\n\n\n<p id=\"wd-1e59e8dd\" class=\"wp-block-wd-paragraph\">The project should therefore balance current demand, spare capacity, cable diameter and termination complexity.<\/p>\n\n\n\n<h2 id=\"wd-ab5fc3f3\" class=\"wp-block-wd-title title\">What Are Control Cables in Industrial Automation?<\/h2>\n\n\n\n<p id=\"wd-8ad68485\" class=\"wp-block-wd-paragraph\"><strong>What are control cables<\/strong> in an automation system? They form the electrical connection between the control logic and the equipment that carries out commands.<\/p>\n\n\n\n<p id=\"wd-f2b2a453\" class=\"wp-block-wd-paragraph\">A typical system can include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PLC<\/li>\n\n\n\n<li>Control panel<\/li>\n\n\n\n<li>Relays<\/li>\n\n\n\n<li>Contactors<\/li>\n\n\n\n<li>Motor starters<\/li>\n\n\n\n<li>Valves<\/li>\n\n\n\n<li>Actuators<\/li>\n\n\n\n<li>Limit switches<\/li>\n\n\n\n<li>Machine sensors<\/li>\n\n\n\n<li>Field junction boxes<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-b83d010e\" class=\"wp-block-wd-paragraph\">Control cabling allows these components to interact reliably.<\/p>\n\n\n\n<p id=\"wd-65d5391e\" class=\"wp-block-wd-paragraph\">However, high-speed industrial Ethernet, precision instrumentation and servo-motor power circuits may require different specialized cable families.<\/p>\n\n\n\n<h2 id=\"wd-37f629ee\" class=\"wp-block-wd-title title\">Control Cable vs Signal Cable<\/h2>\n\n\n\n<p id=\"wd-fc64bd6f\" class=\"wp-block-wd-paragraph\">Control and signal cables can overlap in real industrial systems. However, their design priorities often differ.<\/p>\n\n\n\n<p id=\"wd-264943d3\" class=\"wp-block-wd-paragraph\">Control cables commonly handle switching, commands, interlocks and auxiliary control circuits. They often use multi-core Class 5 conductors and relatively broad conductor-size ranges.<\/p>\n\n\n\n<p id=\"wd-877f53bd\" class=\"wp-block-wd-paragraph\">Signal cables often focus more heavily on low-level signal transmission, capacitance and electromagnetic protection.<\/p>\n\n\n\n<p id=\"wd-3f4a14b3\" class=\"wp-block-wd-paragraph\">For example, LIYY, LIYCY, LIHH and LIHCH belong to ETK&#8217;s separate <a href=\"\/en\/product-cat\/signal-control-cables\/\">signal and low-level control range<\/a>.<\/p>\n\n\n\n<p id=\"wd-07c96f5b\" class=\"wp-block-wd-paragraph\">Therefore, designers should classify the actual circuit rather than choosing between the words \u201csignal\u201d and \u201ccontrol\u201d from a product name alone.<\/p>\n\n\n\n<h2 id=\"wd-621c294f\" class=\"wp-block-wd-title title\">YSLY vs LIYY: Are They the Same?<\/h2>\n\n\n\n<p id=\"wd-6628db69\" class=\"wp-block-wd-paragraph\">No.<\/p>\n\n\n\n<p id=\"wd-a8444e52\" class=\"wp-block-wd-paragraph\">Both can use flexible copper conductors and PVC materials, but they belong to different product families and serve different specification priorities.<\/p>\n\n\n\n<p id=\"wd-7c23c19f\" class=\"wp-block-wd-paragraph\">YSLY commonly addresses industrial control and machine circuits. LIYY commonly serves lower-level signal and electronic-control applications.<\/p>\n\n\n\n<p id=\"wd-4ef4e2a8\" class=\"wp-block-wd-paragraph\">Likewise, YSLCY and LIYCY are both screened families, but this does not make the products interchangeable.<\/p>\n\n\n\n<p id=\"wd-01fc09e8\" class=\"wp-block-wd-paragraph\">Conductor sizes, electrical values, core identification, voltage classes and intended applications can differ.<\/p>\n\n\n\n<p id=\"wd-6c26a622\" class=\"wp-block-wd-paragraph\">For the LI-family structure, see our <a href=\"\/en\/blog\/liycy-vs-liyy-lihch-lihh\/\">LIYCY, LIYY, LIHCH and LIHH comparison<\/a>.<\/p>\n\n\n\n<h2 id=\"wd-035d7f5b\" class=\"wp-block-wd-title title\">Control Cable vs Instrumentation Cable<\/h2>\n\n\n\n<p id=\"wd-fce1e962\" class=\"wp-block-wd-paragraph\">Instrumentation cables focus on measurement and process signals.<\/p>\n\n\n\n<p id=\"wd-44620b56\" class=\"wp-block-wd-paragraph\">Typical circuits include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>4\u201320 mA loops<\/li>\n\n\n\n<li>RTD connections<\/li>\n\n\n\n<li>Pressure transmitters<\/li>\n\n\n\n<li>Flow transmitters<\/li>\n\n\n\n<li>Temperature measurement<\/li>\n\n\n\n<li>Process sensors<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-1dca6705\" class=\"wp-block-wd-paragraph\">As a result, instrumentation cables often use pair or triad architectures. They can also use individual and overall screens.<\/p>\n\n\n\n<p id=\"wd-27701955\" class=\"wp-block-wd-paragraph\">Control cables, by contrast, commonly use multi-core structures for commands, interlocks and equipment control.<\/p>\n\n\n\n<p id=\"wd-ff7d49f1\" class=\"wp-block-wd-paragraph\">For a deeper explanation, see our <a href=\"\/en\/blog\/what-are-instrumentation-cables\/\">instrumentation cable guide<\/a>.<\/p>\n\n\n\n<h2 id=\"wd-b3319c20\" class=\"wp-block-wd-title title\">Control Cable vs Power Cable<\/h2>\n\n\n\n<p id=\"wd-1f683bb5\" class=\"wp-block-wd-paragraph\">A control cable should not automatically replace a power-distribution cable.<\/p>\n\n\n\n<p id=\"wd-760a726a\" class=\"wp-block-wd-paragraph\">Power cables primarily carry electrical energy to loads. Therefore, current-carrying capacity, insulation system and power-cable standards dominate their design.<\/p>\n\n\n\n<p id=\"wd-0992cbed\" class=\"wp-block-wd-paragraph\">Control cables primarily serve command, switching and auxiliary functions.<\/p>\n\n\n\n<p id=\"wd-430bb8cf\" class=\"wp-block-wd-paragraph\">Some control cables can carry low-voltage electrical energy within their specified limits. However, this does not turn them into general-purpose power-distribution cables.<\/p>\n\n\n\n<p id=\"wd-3106b8b3\" class=\"wp-block-wd-paragraph\">The circuit function and applicable product standard should determine the cable family.<\/p>\n\n\n\n<h2 id=\"wd-461a4865\" class=\"wp-block-wd-title title\">Control Cable vs Data Cable<\/h2>\n\n\n\n<p id=\"wd-15fcebb5\" class=\"wp-block-wd-paragraph\">Control cables also differ from Ethernet and other high-frequency data cables.<\/p>\n\n\n\n<p id=\"wd-a943fdba\" class=\"wp-block-wd-paragraph\">A Cat 6 cable, for example, uses controlled twisted-pair geometry and transmission requirements for Ethernet.<\/p>\n\n\n\n<p id=\"wd-1b410419\" class=\"wp-block-wd-paragraph\">A YSLY cable does not become an Ethernet cable simply because it connects two control devices.<\/p>\n\n\n\n<p id=\"wd-3f122f9c\" class=\"wp-block-wd-paragraph\">Therefore, high-speed network communication needs a suitable data-cable system rather than a generic control cable.<\/p>\n\n\n\n<h2 id=\"wd-b208278f\" class=\"wp-block-wd-title title\">Control Cables Near VFDs and Motors<\/h2>\n\n\n\n<p id=\"wd-47221244\" class=\"wp-block-wd-paragraph\">Variable-frequency drives can create significant electromagnetic noise.<\/p>\n\n\n\n<p id=\"wd-316bbf41\" class=\"wp-block-wd-paragraph\">Therefore, control circuits near drives need careful routing and cable selection.<\/p>\n\n\n\n<p id=\"wd-36759335\" class=\"wp-block-wd-paragraph\">Project engineers should review:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Distance from motor power cables<\/li>\n\n\n\n<li>Parallel cable runs<\/li>\n\n\n\n<li>Screening requirement<\/li>\n\n\n\n<li>Screen termination<\/li>\n\n\n\n<li>Grounding and bonding strategy<\/li>\n\n\n\n<li>Control-signal sensitivity<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-3e648d74\" class=\"wp-block-wd-paragraph\">A screened control cable can help in this environment. However, cable screening should complement good EMC design rather than replace it.<\/p>\n\n\n\n<h2 id=\"wd-b1b73122\" class=\"wp-block-wd-title title\">What Are Control Cables Used for in Machinery?<\/h2>\n\n\n\n<p id=\"wd-ba64cf90\" class=\"wp-block-wd-paragraph\">Machine builders use control cables between panels, field devices and internal machine components.<\/p>\n\n\n\n<p id=\"wd-bfac3c5d\" class=\"wp-block-wd-paragraph\">Common applications include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Packaging machinery<\/li>\n\n\n\n<li>Conveyor systems<\/li>\n\n\n\n<li>Assembly machines<\/li>\n\n\n\n<li>Production lines<\/li>\n\n\n\n<li>Pumps<\/li>\n\n\n\n<li>Fans<\/li>\n\n\n\n<li>Compressors<\/li>\n\n\n\n<li>Material-handling systems<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-3dddd773\" class=\"wp-block-wd-paragraph\">In these environments, installers often value flexibility because machine layouts can involve narrow cable routes.<\/p>\n\n\n\n<p id=\"wd-6d6c31d7\" class=\"wp-block-wd-paragraph\">Nevertheless, continuous movement requires a purpose-designed dynamic cable when the duty demands it.<\/p>\n\n\n\n<h2 id=\"wd-413d32b3\" class=\"wp-block-wd-title title\">What Are Control Cables Used for in Building Automation?<\/h2>\n\n\n\n<p id=\"wd-abdf68af\" class=\"wp-block-wd-paragraph\">Building systems also use control circuits.<\/p>\n\n\n\n<p id=\"wd-b540ecf8\" class=\"wp-block-wd-paragraph\">Examples include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>HVAC<\/li>\n\n\n\n<li>Pumps and fans<\/li>\n\n\n\n<li>Building-management systems<\/li>\n\n\n\n<li>Control panels<\/li>\n\n\n\n<li>Actuator circuits<\/li>\n\n\n\n<li>Mechanical services<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-846e73b7\" class=\"wp-block-wd-paragraph\">However, the building environment can add fire and material requirements.<\/p>\n\n\n\n<p id=\"wd-3d323168\" class=\"wp-block-wd-paragraph\">Therefore, designers should evaluate both the electrical function and the installation regulations before selecting PVC or halogen-free products.<\/p>\n\n\n\n<h2 id=\"wd-669bce2e\" class=\"wp-block-wd-title title\">What Are Control Cables Used for in Process Plants?<\/h2>\n\n\n\n<p id=\"wd-26dca316\" class=\"wp-block-wd-paragraph\">Process facilities can contain control, instrumentation, data and power circuits in the same general area.<\/p>\n\n\n\n<p id=\"wd-22aeeb86\" class=\"wp-block-wd-paragraph\">Therefore, correct cable classification becomes especially important.<\/p>\n\n\n\n<p id=\"wd-79976d5a\" class=\"wp-block-wd-paragraph\">A motor-control command may use a control cable. A 4\u201320 mA transmitter can use an instrumentation cable. Meanwhile, Ethernet equipment requires a suitable data cable.<\/p>\n\n\n\n<p id=\"wd-be6d60b4\" class=\"wp-block-wd-paragraph\">This separation helps the project specify the right electrical and EMC performance for each circuit.<\/p>\n\n\n\n<h2 id=\"wd-fe70474d\" class=\"wp-block-wd-title title\">Fixed Installation vs Movement<\/h2>\n\n\n\n<p id=\"wd-f9ac9ee2\" class=\"wp-block-wd-paragraph\">Installation conditions have a major effect on cable life.<\/p>\n\n\n\n<p id=\"wd-0ecdb98b\" class=\"wp-block-wd-paragraph\">A standard flexible control cable can suit fixed installation and can simplify routing during assembly.<\/p>\n\n\n\n<p id=\"wd-5c05335b\" class=\"wp-block-wd-paragraph\">However, frequent movement creates additional mechanical stress.<\/p>\n\n\n\n<p id=\"wd-789a3bc0\" class=\"wp-block-wd-paragraph\">Therefore, designers should specify whether the cable will experience:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fixed installation<\/li>\n\n\n\n<li>Occasional movement<\/li>\n\n\n\n<li>Continuous flexing<\/li>\n\n\n\n<li>Torsion<\/li>\n\n\n\n<li>Drag-chain movement<\/li>\n\n\n\n<li>Repeated acceleration<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-2c6c9e98\" class=\"wp-block-wd-paragraph\">This detail should appear in the RFQ whenever movement forms part of normal operation.<\/p>\n\n\n\n<h2 id=\"wd-8bccb559\" class=\"wp-block-wd-title title\">Indoor and Outdoor Installation<\/h2>\n\n\n\n<p id=\"wd-d2435d40\" class=\"wp-block-wd-paragraph\">Many control-cable applications occur indoors. However, some industrial routes extend outdoors.<\/p>\n\n\n\n<p id=\"wd-2c468aff\" class=\"wp-block-wd-paragraph\">Outdoor installations can expose the cable to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>UV radiation<\/li>\n\n\n\n<li>Moisture<\/li>\n\n\n\n<li>Temperature variation<\/li>\n\n\n\n<li>Abrasion<\/li>\n\n\n\n<li>Mechanical impact<\/li>\n\n\n\n<li>Chemical exposure<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-65ff0e04\" class=\"wp-block-wd-paragraph\">Therefore, an engineer should not assume that every standard indoor control cable suits an external route.<\/p>\n\n\n\n<p id=\"wd-81b5f879\" class=\"wp-block-wd-paragraph\">The complete sheath system and product specification must match the environment.<\/p>\n\n\n\n<h2 id=\"wd-ad8a628e\" class=\"wp-block-wd-title title\">What Are Control Cables Selected By?<\/h2>\n\n\n\n<p id=\"wd-18ec4e6f\" class=\"wp-block-wd-paragraph\"><strong>What are control cables<\/strong> selected by? The correct process starts with the circuit rather than the product code.<\/p>\n\n\n\n<h3 id=\"wd-e9ab0bc3\" class=\"wp-block-wd-title title\">1. Define the Circuit Function<\/h3>\n\n\n\n<p id=\"wd-af8c01bc\" class=\"wp-block-wd-paragraph\">First, identify whether the circuit carries a command, switching function, low-level signal or auxiliary electrical load.<\/p>\n\n\n\n<h3 id=\"wd-80455668\" class=\"wp-block-wd-title title\">2. Select the Voltage Rating<\/h3>\n\n\n\n<p id=\"wd-3a04d48f\" class=\"wp-block-wd-paragraph\">Match 300\/500 V, 450\/750 V or another required class to the exact circuit and product specification.<\/p>\n\n\n\n<h3 id=\"wd-5581a691\" class=\"wp-block-wd-title title\">3. Calculate Conductor Size<\/h3>\n\n\n\n<p id=\"wd-c3f23da2\" class=\"wp-block-wd-paragraph\">Use current, voltage drop, route length and installation conditions.<\/p>\n\n\n\n<h3 id=\"wd-984c9365\" class=\"wp-block-wd-title title\">4. Determine the Core Count<\/h3>\n\n\n\n<p id=\"wd-7c5f59a6\" class=\"wp-block-wd-paragraph\">Include active cores, protective conductor and sensible spare capacity.<\/p>\n\n\n\n<h3 id=\"wd-1567968a\" class=\"wp-block-wd-title title\">5. Choose the Identification System<\/h3>\n\n\n\n<p id=\"wd-02491670\" class=\"wp-block-wd-paragraph\">Specify JZ, OZ, JB, OB or another required core-identification arrangement.<\/p>\n\n\n\n<h3 id=\"wd-0fcf6c5e\" class=\"wp-block-wd-title title\">6. Evaluate EMI<\/h3>\n\n\n\n<p id=\"wd-c43e2026\" class=\"wp-block-wd-paragraph\">Choose screened or unscreened construction according to the electrical environment.<\/p>\n\n\n\n<h3 id=\"wd-1b6b71e2\" class=\"wp-block-wd-title title\">7. Select PVC or Halogen-Free Materials<\/h3>\n\n\n\n<p id=\"wd-1a0daa98\" class=\"wp-block-wd-paragraph\">Match the material system to project and fire requirements.<\/p>\n\n\n\n<h3 id=\"wd-72a00ef0\" class=\"wp-block-wd-title title\">8. Define the Installation Duty<\/h3>\n\n\n\n<p id=\"wd-46fe5347\" class=\"wp-block-wd-paragraph\">State whether the cable remains fixed or experiences repeated movement.<\/p>\n\n\n\n<h3 id=\"wd-7ccdc2ff\" class=\"wp-block-wd-title title\">9. Check the Environment<\/h3>\n\n\n\n<p id=\"wd-d8839e2e\" class=\"wp-block-wd-paragraph\">Consider temperature, UV, moisture, chemicals and mechanical exposure.<\/p>\n\n\n\n<h3 id=\"wd-2becb2a1\" class=\"wp-block-wd-title title\">10. Verify the Datasheet<\/h3>\n\n\n\n<p id=\"wd-db69a9f4\" class=\"wp-block-wd-paragraph\">Finally, confirm conductor resistance, voltage, test requirements, cable diameter and all project-specific limits.<\/p>\n\n\n\n<h2 id=\"wd-5adf3195\" class=\"wp-block-wd-title title\">Control Cable Selection Matrix<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Project Requirement<\/th><th>Good Starting Direction<\/th><\/tr><\/thead><tbody><tr><td>General industrial control, low EMI<\/td><td>Unscreened PVC control cable<\/td><\/tr><tr><td>Control circuit near electrical noise<\/td><td>Braid-screened control cable<\/td><\/tr><tr><td>Screening plus additional inner sheath<\/td><td>YSLYCY-type construction<\/td><\/tr><tr><td>Halogen-free material requirement<\/td><td>HSLH-type family<\/td><\/tr><tr><td>Halogen-free plus screening<\/td><td>HSLCH-type family<\/td><\/tr><tr><td>Number-coded cores with PE conductor<\/td><td>JZ configuration<\/td><\/tr><tr><td>Number-coded cores without PE conductor<\/td><td>OZ configuration<\/td><\/tr><tr><td>Higher voltage-class requirement<\/td><td>Check suitable 450\/750 V family<\/td><\/tr><tr><td>Continuous dynamic movement<\/td><td>Dedicated continuous-flex cable, not standard flexible control cable by default<\/td><\/tr><tr><td>Precision process measurement<\/td><td>Evaluate instrumentation cable instead<\/td><\/tr><tr><td>Ethernet communication<\/td><td>Use suitable Data\/LAN cable<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p id=\"wd-61dded63\" class=\"wp-block-wd-paragraph\">This table provides a starting point. The final product must still match the exact circuit and installation conditions.<\/p>\n\n\n\n<h2 id=\"wd-92547226\" class=\"wp-block-wd-title title\">Common Control Cable Selection Mistakes<\/h2>\n\n\n\n<h3 id=\"wd-b9a22072\" class=\"wp-block-wd-title title\">Assuming Every Flexible Cable Is Continuous-Flex<\/h3>\n\n\n\n<p id=\"wd-075d0ada\" class=\"wp-block-wd-paragraph\">Class 5 conductor flexibility does not automatically provide drag-chain or robotic performance.<\/p>\n\n\n\n<h3 id=\"wd-40421fc9\" class=\"wp-block-wd-title title\">Using a Screened Cable Everywhere<\/h3>\n\n\n\n<p id=\"wd-65ef4a89\" class=\"wp-block-wd-paragraph\">A metallic braid adds cost, diameter and termination work. Use it where the EMC environment justifies it.<\/p>\n\n\n\n<h3 id=\"wd-846a3d87\" class=\"wp-block-wd-title title\">Assuming Halogen-Free Means Fire Resistant<\/h3>\n\n\n\n<p id=\"wd-8e42c05b\" class=\"wp-block-wd-paragraph\">Material composition and circuit integrity describe different performance areas.<\/p>\n\n\n\n<h3 id=\"wd-19495fd8\" class=\"wp-block-wd-title title\">Ignoring Voltage Rating<\/h3>\n\n\n\n<p id=\"wd-2a642fcf\" class=\"wp-block-wd-paragraph\">Two similar cable families can carry different voltage designations.<\/p>\n\n\n\n<h3 id=\"wd-8eb9079f\" class=\"wp-block-wd-title title\">Selecting Conductor Size by Habit<\/h3>\n\n\n\n<p id=\"wd-e4117d94\" class=\"wp-block-wd-paragraph\">Current, voltage drop and route conditions should determine cross-section.<\/p>\n\n\n\n<h3 id=\"wd-0465608a\" class=\"wp-block-wd-title title\">Confusing Control and Instrumentation Cables<\/h3>\n\n\n\n<p id=\"wd-b096d5ff\" class=\"wp-block-wd-paragraph\">Process measurement often requires different pair, triad and screening architectures.<\/p>\n\n\n\n<h3 id=\"wd-80d9cb42\" class=\"wp-block-wd-title title\">Using Control Cable for Ethernet<\/h3>\n\n\n\n<p id=\"wd-2b5dd3b1\" class=\"wp-block-wd-paragraph\">High-speed Ethernet requires a cable designed for the applicable transmission category.<\/p>\n\n\n\n<h3 id=\"wd-91236ff0\" class=\"wp-block-wd-title title\">Ignoring Core Identification<\/h3>\n\n\n\n<p id=\"wd-299c0791\" class=\"wp-block-wd-paragraph\">JZ, OZ and other configurations affect installation and protective-conductor availability.<\/p>\n\n\n\n<h3 id=\"wd-fe576bbc\" class=\"wp-block-wd-title title\">Assuming Every Outdoor Route Uses the Same Cable<\/h3>\n\n\n\n<p id=\"wd-f52bd9f1\" class=\"wp-block-wd-paragraph\">UV, moisture and mechanical conditions can vary significantly between installations.<\/p>\n\n\n\n<h2 id=\"wd-9535fac4\" class=\"wp-block-wd-title title\">What Should a Control Cable RFQ Include?<\/h2>\n\n\n\n<p id=\"wd-d80857dc\" class=\"wp-block-wd-paragraph\">When buyers ask <strong>what are control cables<\/strong> for a specific project, a complete RFQ provides a much better answer than a product name alone.<\/p>\n\n\n\n<p id=\"wd-f95fc589\" class=\"wp-block-wd-paragraph\">Include at least:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Required cable family or performance description<\/li>\n\n\n\n<li>Number of cores<\/li>\n\n\n\n<li>Conductor cross-section<\/li>\n\n\n\n<li>Conductor class<\/li>\n\n\n\n<li>Operating voltage<\/li>\n\n\n\n<li>Screened or unscreened construction<\/li>\n\n\n\n<li>Required screen type<\/li>\n\n\n\n<li>JZ, OZ, JB, OB or other identification<\/li>\n\n\n\n<li>PVC or halogen-free material requirement<\/li>\n\n\n\n<li>Fire-performance requirement<\/li>\n\n\n\n<li>Indoor or outdoor installation<\/li>\n\n\n\n<li>Fixed or dynamic duty<\/li>\n\n\n\n<li>Operating temperature<\/li>\n\n\n\n<li>UV or chemical exposure where relevant<\/li>\n\n\n\n<li>Maximum cable diameter where relevant<\/li>\n\n\n\n<li>Required packing length<\/li>\n\n\n\n<li>Cable marking<\/li>\n\n\n\n<li>Applicable standards<\/li>\n\n\n\n<li>Test reports and documentation<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-09ccbb80\" class=\"wp-block-wd-paragraph\">As a result, manufacturers can quote comparable constructions. In addition, procurement teams avoid comparing products that share a similar name but use different technical designs.<\/p>\n\n\n\n<h2 id=\"wd-58dca814\" class=\"wp-block-wd-title title\">ETK Kablo Control Cable Solutions<\/h2>\n\n\n\n<p id=\"wd-170327cc\" class=\"wp-block-wd-paragraph\">ETK Kablo manufactures flexible control cables for industrial automation, machine builders, panel manufacturers, HVAC systems, production plants and commercial infrastructure.<\/p>\n\n\n\n<p id=\"wd-055168fd\" class=\"wp-block-wd-paragraph\">The portfolio includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>YSLY-JZ and related unscreened PVC constructions<\/li>\n\n\n\n<li>YSLCY screened PVC control cables<\/li>\n\n\n\n<li>YSLYCY screened constructions with inner sheath<\/li>\n\n\n\n<li>HSLH halogen-free families<\/li>\n\n\n\n<li>HSLCH screened halogen-free families<\/li>\n\n\n\n<li>Foil and braid-screened variants<\/li>\n\n\n\n<li>300\/500 V families<\/li>\n\n\n\n<li>450\/750 V families<\/li>\n\n\n\n<li>Different core counts and cross-sections<\/li>\n\n\n\n<li>Project-specific identification and marking options<\/li>\n<\/ul>\n\n\n\n<p id=\"wd-51cf2eaa\" class=\"wp-block-wd-paragraph\">Therefore, project engineers can select screening, material, conductor size, voltage and core arrangement according to the actual automation circuit.<\/p>\n\n\n\n<h2 id=\"wd-b16e7d32\" class=\"wp-block-wd-title title\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 id=\"wd-a7e6c8ce\" class=\"wp-block-wd-title title\">What are control cables?<\/h3>\n\n\n\n<p id=\"wd-3b2d340d\" class=\"wp-block-wd-paragraph\"><strong>What are control cables?<\/strong> They are multi-core electrical cables used for commands, switching, control functions and suitable low-voltage auxiliary circuits between automation equipment.<\/p>\n\n\n\n<h3 id=\"wd-653cdd0d\" class=\"wp-block-wd-title title\">Where are control cables used?<\/h3>\n\n\n\n<p id=\"wd-075e9dea\" class=\"wp-block-wd-paragraph\">They commonly serve industrial machinery, PLC systems, control panels, HVAC, conveyors, production lines, actuators and building automation.<\/p>\n\n\n\n<h3 id=\"wd-1ff0a954\" class=\"wp-block-wd-title title\">What is YSLY cable?<\/h3>\n\n\n\n<p id=\"wd-ab774600\" class=\"wp-block-wd-paragraph\">YSLY is an unscreened flexible PVC control-cable family with stranded copper conductors, PVC insulation and PVC outer sheath.<\/p>\n\n\n\n<h3 id=\"wd-def6e8d9\" class=\"wp-block-wd-title title\">What is YSLCY cable?<\/h3>\n\n\n\n<p id=\"wd-7400a1f1\" class=\"wp-block-wd-paragraph\">YSLCY adds a tinned-copper braid screen to a flexible PVC control-cable construction. Therefore, it suits circuits that require additional EMI protection.<\/p>\n\n\n\n<h3 id=\"wd-63ca0f23\" class=\"wp-block-wd-title title\">What is YSLYCY cable?<\/h3>\n\n\n\n<p id=\"wd-f9f74950\" class=\"wp-block-wd-paragraph\">YSLYCY uses screening together with an additional inner-sheath layer. This construction differs from ETK&#8217;s standard YSLCY design.<\/p>\n\n\n\n<h3 id=\"wd-57453c32\" class=\"wp-block-wd-title title\">What does JZ mean?<\/h3>\n\n\n\n<p id=\"wd-59e22856\" class=\"wp-block-wd-paragraph\">JZ commonly indicates numbered cores together with a green-yellow protective conductor.<\/p>\n\n\n\n<h3 id=\"wd-4e199fc6\" class=\"wp-block-wd-title title\">What does OZ mean?<\/h3>\n\n\n\n<p id=\"wd-9c00b84d\" class=\"wp-block-wd-paragraph\">OZ commonly indicates numbered cores without a green-yellow protective conductor.<\/p>\n\n\n\n<h3 id=\"wd-a4d288fb\" class=\"wp-block-wd-title title\">Are control cables shielded?<\/h3>\n\n\n\n<p id=\"wd-115c0fc5\" class=\"wp-block-wd-paragraph\">Some are and some are not. The electromagnetic environment should determine whether the project needs screening.<\/p>\n\n\n\n<h3 id=\"wd-a7304225\" class=\"wp-block-wd-title title\">Are control cables flexible?<\/h3>\n\n\n\n<p id=\"wd-42662370\" class=\"wp-block-wd-paragraph\">Many industrial control cables use Class 5 flexible copper conductors. However, this does not automatically make them suitable for continuous drag-chain movement.<\/p>\n\n\n\n<h3 id=\"wd-211283d1\" class=\"wp-block-wd-title title\">What voltage are control cables?<\/h3>\n\n\n\n<p id=\"wd-a4edd2a1\" class=\"wp-block-wd-paragraph\">Voltage depends on the specific product. Common ETK families include 300\/500 V and 450\/750 V constructions.<\/p>\n\n\n\n<h3 id=\"wd-1a19ba16\" class=\"wp-block-wd-title title\">Is a control cable the same as a signal cable?<\/h3>\n\n\n\n<p id=\"wd-5ce1e707\" class=\"wp-block-wd-paragraph\">Not always. The families can overlap, but signal cables often prioritize low-level transmission and EMI behaviour while control cables commonly handle commands and auxiliary control functions.<\/p>\n\n\n\n<h3 id=\"wd-c3b5eaf3\" class=\"wp-block-wd-title title\">Is a control cable the same as an instrumentation cable?<\/h3>\n\n\n\n<p id=\"wd-5bfe3b21\" class=\"wp-block-wd-paragraph\">No. Instrumentation cables often use pair or triad constructions for measurement and process signals. Control cables more commonly use multi-core architectures for commands and machine-control circuits.<\/p>\n\n\n\n<h3 id=\"wd-df18b05c\" class=\"wp-block-wd-title title\">Can control cable carry power?<\/h3>\n\n\n\n<p id=\"wd-bc9ed1f2\" class=\"wp-block-wd-paragraph\">A suitable control cable can carry electrical energy within its specified circuit, conductor size and voltage limits. However, it should not automatically replace a power-distribution cable.<\/p>\n\n\n\n<h3 id=\"wd-cbdacc86\" class=\"wp-block-wd-title title\">Is LSZH control cable fire resistant?<\/h3>\n\n\n\n<p id=\"wd-3b836f2d\" class=\"wp-block-wd-paragraph\">Not automatically. Halogen-free material characteristics, flame propagation and fire-resistant circuit integrity are separate performance requirements.<\/p>\n\n\n\n<h3 id=\"wd-6942c097\" class=\"wp-block-wd-title title\">Which control cable should I choose?<\/h3>\n\n\n\n<p id=\"wd-8ba885ff\" class=\"wp-block-wd-paragraph\">Choose according to circuit function, voltage, conductor size, core count, electromagnetic environment, material requirement and installation duty.<\/p>\n\n\n\n<h2 id=\"wd-63f35cc4\" class=\"wp-block-wd-title title\">Conclusion: What Are Control Cables and How Should You Choose Them?<\/h2>\n\n\n\n<p id=\"wd-d9775f76\" class=\"wp-block-wd-paragraph\"><strong>What are control cables?<\/strong> They are the electrical links that allow automation equipment to send commands, switch functions and coordinate machinery and building systems.<\/p>\n\n\n\n<p id=\"wd-019eac08\" class=\"wp-block-wd-paragraph\">However, one universal control-cable construction does not exist. An unscreened YSLY-type design can provide an efficient solution in a controlled electromagnetic environment. By contrast, YSLCY or YSLYCY can add screening when interference becomes more important.<\/p>\n\n\n\n<p id=\"wd-6c47561c\" class=\"wp-block-wd-paragraph\">Material choice creates another decision. PVC provides a practical industrial solution for many applications, while halogen-free families serve projects with different smoke and material requirements.<\/p>\n\n\n\n<p id=\"wd-ba0fb76d\" class=\"wp-block-wd-paragraph\">Next, define conductor size, core count and voltage rating. In addition, specify the correct JZ, OZ or other core-identification arrangement.<\/p>\n\n\n\n<p id=\"wd-1838d696\" class=\"wp-block-wd-paragraph\">Finally, consider the real installation duty. A flexible Class 5 conductor can simplify fixed machine wiring, but continuous movement requires a cable designed for repeated dynamic stress.<\/p>\n\n\n\n<p id=\"wd-16a652f0\" class=\"wp-block-wd-paragraph\">Therefore, the best control cable is not simply the most flexible, most heavily screened or highest-voltage option. It is the construction that matches the electrical circuit, EMC environment, installation conditions and project requirements without unnecessary overengineering.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading time: <\/span> <span class=\"rt-time\"> 13<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>Component Typical Option Main Function Conductor Class 5 stranded copper Electrical conduction and installation flexibility Insulation PVC or halogen-free compound<\/p>\n","protected":false},"author":5,"featured_media":5407,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[87],"tags":[],"class_list":["post-5406","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-posts"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Are Control Cables? Types, Uses &amp; Selection Guide<\/title>\n<meta name=\"description\" content=\"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Are Control Cables? Types, Uses &amp; Selection Guide\" \/>\n<meta property=\"og:description\" content=\"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/\" \/>\n<meta property=\"og:site_name\" content=\"ETK Kablo English\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-07T18:35:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-09T12:32:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"450\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"ETK Kablo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"ETK Kablo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"17 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/\",\"url\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/\",\"name\":\"What Are Control Cables? Types, Uses & Selection Guide\",\"isPartOf\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg\",\"datePublished\":\"2025-10-07T18:35:10+00:00\",\"dateModified\":\"2026-10-09T12:32:18+00:00\",\"author\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/1962fb9ee162af8a5f2777f5debeffea\"},\"description\":\"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage\",\"url\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg\",\"contentUrl\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg\",\"width\":450,\"height\":300,\"caption\":\"What are control cables? Comparison of YSLY, YSLCY, YSLYCY, screened, unscreened, PVC and halogen-free control cable types\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.etkkablo.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Are Control Cables? Types, Uses &amp; Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/#website\",\"url\":\"https:\/\/www.etkkablo.com\/en\/\",\"name\":\"ETK Kablo English\",\"description\":\"ETK Kablo is a leading manufacturer of fiber optic, telecom, and data cables. Discover high-performance cable solutions for global communication networks.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.etkkablo.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/1962fb9ee162af8a5f2777f5debeffea\",\"name\":\"ETK Kablo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/f27f0308882571f5048a991b52ce943e0b28f29a75fd44de57d60792635cd1e4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/f27f0308882571f5048a991b52ce943e0b28f29a75fd44de57d60792635cd1e4?s=96&d=mm&r=g\",\"caption\":\"ETK Kablo\"},\"sameAs\":[\"https:\/\/www.etkkablo.com\"],\"url\":\"https:\/\/www.etkkablo.com\/en\/blog\/author\/etkadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Are Control Cables? Types, Uses & Selection Guide","description":"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/","og_locale":"en_US","og_type":"article","og_title":"What Are Control Cables? Types, Uses & Selection Guide","og_description":"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.","og_url":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/","og_site_name":"ETK Kablo English","article_published_time":"2025-10-07T18:35:10+00:00","article_modified_time":"2026-10-09T12:32:18+00:00","og_image":[{"width":450,"height":300,"url":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg","type":"image\/jpeg"}],"author":"ETK Kablo","twitter_card":"summary_large_image","twitter_misc":{"Written by":"ETK Kablo","Est. reading time":"17 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/","url":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/","name":"What Are Control Cables? Types, Uses & Selection Guide","isPartOf":{"@id":"https:\/\/www.etkkablo.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage"},"image":{"@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage"},"thumbnailUrl":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg","datePublished":"2025-10-07T18:35:10+00:00","dateModified":"2026-10-09T12:32:18+00:00","author":{"@id":"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/1962fb9ee162af8a5f2777f5debeffea"},"description":"What are control cables? Learn YSLY, screened vs unshielded designs, PVC vs LSZH, JZ\/OZ coding, voltage ratings and industrial uses.","breadcrumb":{"@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#primaryimage","url":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg","contentUrl":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/10\/54ee12ab-8c95-4280-b9f5-95e8fa916de3.jpg","width":450,"height":300,"caption":"What are control cables? Comparison of YSLY, YSLCY, YSLYCY, screened, unscreened, PVC and halogen-free control cable types"},{"@type":"BreadcrumbList","@id":"https:\/\/www.etkkablo.com\/en\/blog\/what-are-control-cables\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.etkkablo.com\/en\/"},{"@type":"ListItem","position":2,"name":"What Are Control Cables? Types, Uses &amp; Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.etkkablo.com\/en\/#website","url":"https:\/\/www.etkkablo.com\/en\/","name":"ETK Kablo English","description":"ETK Kablo is a leading manufacturer of fiber optic, telecom, and data cables. Discover high-performance cable solutions for global communication networks.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.etkkablo.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/1962fb9ee162af8a5f2777f5debeffea","name":"ETK Kablo","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.etkkablo.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/f27f0308882571f5048a991b52ce943e0b28f29a75fd44de57d60792635cd1e4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f27f0308882571f5048a991b52ce943e0b28f29a75fd44de57d60792635cd1e4?s=96&d=mm&r=g","caption":"ETK Kablo"},"sameAs":["https:\/\/www.etkkablo.com"],"url":"https:\/\/www.etkkablo.com\/en\/blog\/author\/etkadmin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/posts\/5406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/comments?post=5406"}],"version-history":[{"count":3,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/posts\/5406\/revisions"}],"predecessor-version":[{"id":6026,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/posts\/5406\/revisions\/6026"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/media\/5407"}],"wp:attachment":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/media?parent=5406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/categories?post=5406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/tags?post=5406"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}