{"id":2552,"date":"2025-07-20T23:10:25","date_gmt":"2025-07-20T20:10:25","guid":{"rendered":"https:\/\/demo.webz.com.tr\/en\/?post_type=product&#038;p=2552"},"modified":"2025-11-05T10:04:14","modified_gmt":"2025-11-05T07:04:14","slug":"nhxh-j-061kv-fe180-e90-fire-resistant-cable","status":"publish","type":"product","link":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/","title":{"rendered":"(N)HXH-J 0.6\/1kV FE180 E90 Fire Resistant Cable"},"content":{"rendered":"\n<div id=\"wd-74f8e120\" class=\"wp-block-wd-tabs wd-tabs tabs-design-simple\">\n<div id=\"wd-6a42a150\" class=\"wp-block-wd-tabs-header wd-tabs-header\"><div class=\"wd-nav-wrapper wd-nav-tabs-wrapper\"><ul class=\"wd-nav wd-nav-tabs wd-style-default wd-icon-pos-start wd-style-default\"><li class=\"\"><a href=\"#\" class=\"wd-nav-link test\"><span class=\"nav-link-text wd-tabs-title\">Cable Construction<\/span><\/a><\/li><li class=\"\"><a href=\"#\" class=\"wd-nav-link test\"><span class=\"nav-link-text wd-tabs-title\">Technical Data<\/span><\/a><\/li><li class=\"\"><a href=\"#\" class=\"wd-nav-link test\"><span class=\"nav-link-text wd-tabs-title\">Standards<\/span><\/a><\/li><li class=\"\"><a href=\"#\" class=\"wd-nav-link test\"><span class=\"nav-link-text wd-tabs-title\">Mechanical Characteristics<\/span><\/a><\/li><li class=\"\"><a href=\"#\" class=\"wd-nav-link test\"><div class=\"img-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"29\" height=\"32\" class=\"wp-image-951\" src=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/06\/PDF_33.png\" alt=\"\"\/><\/div><span class=\"nav-link-text wd-tabs-title\">PDF<\/span><\/a><\/li><\/ul><\/div><\/div>\n\n\n\n<div id=\"wd-c12f6d6f\" class=\"wp-block-wd-tabs-content wd-tabs-content-wrapper\">\n<div id=\"wd-fc8a96a7\" class=\"wp-block-wd-tabs-content-tab wd-tab-content\">\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>1 &#8211; Conductor<\/td><td>:<\/td><td>Class 1 solid or Class 2 stranded electrolytic copper conductor (IEC 60228, DIN VDE 0295, EN 60228).<\/td><\/tr><tr><td>2 &#8211; Insulation<\/td><td>:<\/td><td>Cross-linked polymer compound in ceramic form (VDE 0815).<\/td><\/tr><tr><td>3 &#8211; Stranding<\/td><td>:<\/td><td>Insulations are stranded into layers.<\/td><\/tr><tr><td>4 &#8211; Filling<\/td><td>:<\/td><td>Halogen-free compund.<\/td><\/tr><tr><td>5 &#8211; Outer Jacket<\/td><td>:<\/td><td>UV resistant halogen-free outer jacket. RAL 2008 (Orange)<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div id=\"wd-6f348c98\" class=\"wp-block-wd-tabs-content-tab wd-tab-content\">\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th><strong>Cross<br>Section<\/strong><\/th><th><strong>Conductor Resistance<br>\u03a9\/km<br>(20 \u00b0C)<\/strong><\/th><th><strong>Operating<br>Voltage<br><br>V DC<\/strong><\/th><th><strong>Test Voltage<br><br>(@ 1 minute)<br>V<\/strong><\/th><\/tr><\/thead><tbody><tr><td>0.50 mm\u00b2<\/td><td>36.0<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>0.75 mm\u00b2<\/td><td>24.5<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>1.00 mm\u00b2<\/td><td>18.1<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>1.50 mm\u00b2<\/td><td>12.1<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>2.50 mm\u00b2<\/td><td>7.41<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>4.00 mm\u00b2<\/td><td>4.61<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>6.00 mm\u00b2<\/td><td>3.08<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>10.00 mm\u00b2<\/td><td>1.83<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>16.00 mm\u00b2<\/td><td>1.15<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>25.00 mm\u00b2<\/td><td>0.727<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><tr><td>35.00 mm\u00b2<\/td><td>0.524<\/td><td>600\/1000<\/td><td>4000<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div id=\"wd-3a4836d1\" class=\"wp-block-wd-tabs-content-tab wd-tab-content\">\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th><strong>Smoke Density Test<\/strong><\/th><th><strong>Corrosive Gas Test<\/strong><\/th><th><strong>Halogen-free Test<\/strong><\/th><th><strong>Flame Propagation Test<\/strong><\/th><th><strong>Flame Retardancy Test<\/strong><\/th><\/tr><\/thead><tbody><tr><td>IEC 61034-2,<br>VDE 0482-1034-2,<br>BS EN 61034-2<\/td><td>IEC 60754-2,<br>VDE 0482-267-2-3,<br>BS EN 50267-2-3<\/td><td>IEC 60754-1,<br>VDE 0482-267-2-1,<br>BS EN 50267-2-1<\/td><td>IEC 60332-3-24,<br>VDE 0482-332-3-24,<br>EN 60332-2-24<\/td><td>IEC 60332-1-2,<br>VDE 0482-332-1-2,<br>BS EN 60332-1-2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th><strong>Circuit Integrity Test<br>(FE180)<\/strong><\/th><th><strong>Cable System Circuit Integrity Test<br>(E30 \/ E60 \/ E90)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>IEC 60331-21<\/td><td>DIN 4102-12<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div id=\"wd-7620b3d1\" class=\"wp-block-wd-tabs-content-tab wd-tab-content\">\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th><strong>Bending Radius<\/strong><\/th><th><strong>Temperature Range<br>Operating<\/strong><\/th><\/tr><\/thead><tbody><tr><td>10xD mm<\/td><td>-40\u00b0C ~ +90\u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div id=\"wd-5e6223ff\" class=\"wp-block-wd-tabs-content-tab wd-tab-content\">\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/ccb62913-1526-494e-a883-80a7f47f9898.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of ccb62913-1526-494e-a883-80a7f47f9898.\"><\/object><a id=\"wp-block-file--media-e4ba6ee7-f383-4830-bbc1-50ed00b61587\" href=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/ccb62913-1526-494e-a883-80a7f47f9898.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Open in a new tab<\/a><a href=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/ccb62913-1526-494e-a883-80a7f47f9898.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-e4ba6ee7-f383-4830-bbc1-50ed00b61587\">Download<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 id=\"wd-cb3e459b\" class=\"wp-block-wd-title title\">(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Power Cable<\/h2>\n\n\n\n<p id=\"wd-4cfb05f5\" class=\"wp-block-wd-paragraph\"><strong><a href=\"https:\/\/www.etkkablo.com\/en\/\">ETK Kablo<\/a>\u2019s (N)HXH-J 0.6\/1kV FE180 E90<\/strong> is a <strong>halogen-free, <a href=\"https:\/\/www.etkkablo.com\/en\/product-cat\/fire-resistant-power-cables\/\">fire-resistant power cable<\/a><\/strong> engineered to ensure <strong>power continuity<\/strong> and <strong>circuit integrity<\/strong> in critical systems during fire conditions. Certified with <strong>FE180<\/strong> and <strong>E90<\/strong> performance ratings, this cable provides reliable energy transmission for <strong>emergency lighting, <a href=\"https:\/\/www.etkkablo.com\/en\/product-cat\/fire-alarm-cables\/\">fire alarm<\/a>, smoke extraction, and evacuation systems<\/strong> for up to 90 minutes under flame and mechanical stress.<\/p>\n\n\n\n<h2 id=\"wd-950e3e98\" class=\"wp-block-wd-title title\">Reliable Fire Resistance and Circuit Integrity<\/h2>\n\n\n\n<p id=\"wd-a3c18740\" class=\"wp-block-wd-paragraph\">The <strong>FE180<\/strong> classification confirms that the cable\u2019s conductors maintain <strong>electrical functionality for 180 minutes<\/strong> under fire exposure, while the <strong>E90<\/strong> rating guarantees <strong>mechanical integrity for 90 minutes<\/strong> under flame and impact. These properties make <strong>(N)HXH-J FE180 E90<\/strong> ideal for use in <strong>safety-critical applications<\/strong> where continuous power supply is essential during fire emergencies.<\/p>\n\n\n\n<h2 id=\"wd-79ca835f\" class=\"wp-block-wd-title title\">Halogen-Free and Flame-Retardant Construction<\/h2>\n\n\n\n<p id=\"wd-1079353f\" class=\"wp-block-wd-paragraph\">Constructed with <strong>copper conductors<\/strong> and a <strong>Low Smoke Zero Halogen (LSZH)<\/strong> insulation and sheath, this cable ensures <strong>minimal smoke and toxic gas emission<\/strong> in the event of fire. Its <strong>non-corrosive, flame-retardant<\/strong> materials provide enhanced safety for people and sensitive electronic systems, making it suitable for <strong>public buildings, hospitals, airports, tunnels, and high-rise complexes<\/strong>.<\/p>\n\n\n\n<h2 id=\"wd-79179a61\" class=\"wp-block-wd-title title\">Applications and Installation Areas<\/h2>\n\n\n\n<p id=\"wd-b7799e7e\" class=\"wp-block-wd-paragraph\">The <strong>(N)HXH-J 0.6\/1kV FE180 E90<\/strong> is designed for <strong>fixed indoor installations<\/strong> where <strong>fire survival and operational reliability<\/strong> are required. It can be installed on <strong>cable trays, inside conduits, or embedded in concrete<\/strong>, supporting consistent power delivery in <strong>emergency power networks<\/strong> and <strong>building safety systems<\/strong>.<\/p>\n\n\n\n<h2 id=\"wd-531ac696\" class=\"wp-block-wd-title title\">Compliance and Quality Standards<\/h2>\n\n\n\n<p id=\"wd-fb1de80d\" class=\"wp-block-wd-paragraph\">ETK Kablo\u2019s<a href=\"https:\/\/www.etkkablo.com\/en\/product-cat\/fire-resistant-cables\/\"> fire-resistant<\/a> <strong>(N)HXH-J cable<\/strong> complies with major international and European standards, including <strong>IEC 60331<\/strong> (circuit integrity), <strong>IEC 60332-1\/3<\/strong> (flame retardancy), and <strong>VDE 0276-604<\/strong> (construction and performance). It is <strong>CPR-compliant<\/strong> and available in classifications such as <strong>Cca or Dca<\/strong> upon request, ensuring complete conformity to building safety regulations.<\/p>\n\n\n\n<h2 id=\"wd-2e1e742d\" class=\"wp-block-wd-title title\">Why Choose ETK Kablo\u2019s (N)HXH-J FE180 E90?<\/h2>\n\n\n\n<p id=\"wd-a21c7b31\" class=\"wp-block-wd-paragraph\"><em>Choose <strong>ETK Kablo\u2019s (N)HXH-J 0.6\/1kV FE180 E90<\/strong> \u2014 the <strong>halogen-free fire-resistant power cable<\/strong> built for <strong>critical infrastructure and emergency energy systems<\/strong>. With verified <strong>FE180 \/ E90 fire endurance<\/strong>, <strong>low smoke emission,<\/strong> and <strong>CPR compliance<\/strong>, it provides <strong>safe, reliable, and continuous power transmission<\/strong> when protection matters most.<\/em><\/p>\n\n\n\n<h2 id=\"wd-6e598016\" class=\"wp-block-wd-title title\">Frequently Asked Questions about (N)HXH-J FE180 E90 Fire-Resistant Cable<\/h2>\n\n\n\n<h3 id=\"wd-9a58d34f\" class=\"wp-block-wd-title title\">What is the difference between NHXH and NHXCH?<\/h3>\n\n\n\n<p id=\"wd-12542cc1\" class=\"wp-block-wd-paragraph\">The main difference lies in the <strong>shielding<\/strong>. <strong>NHXH<\/strong> cables are <strong>unshielded halogen-free power cables<\/strong> designed for fire-resistant installations, while <strong>NHXCH<\/strong> cables include a <strong>collective copper screen (C)<\/strong> that provides <strong>electromagnetic interference (EMI) protection<\/strong>. NHXCH is used where signal or control circuits require shielding in addition to fire resistance.<\/p>\n\n\n\n<h3 id=\"wd-4ed97055\" class=\"wp-block-wd-title title\">What is NHXMH cable?<\/h3>\n\n\n\n<p id=\"wd-121669da\" class=\"wp-block-wd-paragraph\"><strong>NHXMH<\/strong> is a <strong>halogen-free, flame-retardant power cable<\/strong> that does <strong>not offer circuit integrity<\/strong> under fire conditions like FE180 or E90-rated cables. It is commonly used in <strong>residential, commercial, and industrial installations<\/strong> where low smoke and halogen-free performance are required, but full fire endurance is not critical.<\/p>\n\n\n\n<h3 id=\"wd-09053ffb\" class=\"wp-block-wd-title title\">What is a N2XH cable?<\/h3>\n\n\n\n<p id=\"wd-6c9a9bfe\" class=\"wp-block-wd-paragraph\"><strong>N2XH<\/strong> cables are <strong>halogen-free, XLPE-insulated power cables<\/strong> for fixed installations up to <strong>0.6\/1kV<\/strong>. Unlike NHXH cables, which use <strong>thermoplastic LSZH insulation<\/strong>, N2XH uses <strong>cross-linked polyethylene (XLPE)<\/strong>, providing higher temperature resistance and current-carrying capacity. However, N2XH is <strong>not designed for functional integrity during fire exposure<\/strong>.<\/p>\n\n\n\n<h3 id=\"wd-c0a31191\" class=\"wp-block-wd-title title\">What is FE180 E90?<\/h3>\n\n\n\n<p id=\"wd-6e222a90\" class=\"wp-block-wd-paragraph\"><strong>FE180<\/strong> and <strong>E90<\/strong> are international fire resistance classifications. <strong>FE180<\/strong> means the cable\u2019s conductors maintain <strong>electrical functionality for 180 minutes<\/strong> under direct flame, while <strong>E90<\/strong> indicates the entire cable maintains <strong>mechanical integrity and circuit continuity for 90 minutes<\/strong>. Together, they certify that ETK Kablo\u2019s <strong>(N)HXH-J 0.6\/1kV FE180 E90<\/strong> cable continues to supply power safely during extended fire conditions.<\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":2553,"template":"","meta":[],"product_brand":[],"product_cat":[142],"product_tag":[],"class_list":{"0":"post-2552","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fire-resistant-power-cables","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.1.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo<\/title>\n<meta name=\"description\" content=\"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo\" \/>\n<meta property=\"og:description\" content=\"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/\" \/>\n<meta property=\"og:site_name\" content=\"ETK Kablo English\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-05T07:04:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/\",\"url\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/\",\"name\":\"(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo\",\"isPartOf\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg\",\"datePublished\":\"2025-07-20T20:10:25+00:00\",\"dateModified\":\"2025-11-05T07:04:14+00:00\",\"description\":\"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage\",\"url\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg\",\"contentUrl\":\"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg\",\"width\":2000,\"height\":500,\"caption\":\"(N)HXH-J 0.6\/1 kV FE180 E90 fire resistant cable \u2013 halogen-free LSZH insulated and sheathed, 180 min insulation & 90 min circuit integrity \u2013 ETK Kablo\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.etkkablo.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u00dcr\u00fcn Katalo\u011fu\",\"item\":\"https:\/\/www.etkkablo.com\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"(N)HXH-J 0.6\/1kV FE180 E90 Fire Resistant Cable\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.etkkablo.com\/en\/#website\",\"url\":\"https:\/\/www.etkkablo.com\/en\/\",\"name\":\"ETK Kablo English\",\"description\":\"ETK Kablo is a leading manufacturer of fiber optic, telecom, and data cables. Discover high-performance cable solutions for global communication networks.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.etkkablo.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo","description":"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/","og_locale":"en_US","og_type":"article","og_title":"(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo","og_description":"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.","og_url":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/","og_site_name":"ETK Kablo English","article_modified_time":"2025-11-05T07:04:14+00:00","og_image":[{"width":2000,"height":500,"url":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/","url":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/","name":"(N)HXH-J 0.6\/1kV FE180 E90 Fire-Resistant Cable | ETK Kablo","isPartOf":{"@id":"https:\/\/www.etkkablo.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage"},"image":{"@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage"},"thumbnailUrl":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg","datePublished":"2025-07-20T20:10:25+00:00","dateModified":"2025-11-05T07:04:14+00:00","description":"Halogen-free (N)HXH-J 0.6\/1kV cable ensures FE180 E90 circuit integrity during fire. Ideal for buildings requiring safe, uninterrupted power supply.","breadcrumb":{"@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#primaryimage","url":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg","contentUrl":"https:\/\/www.etkkablo.com\/en\/wp-content\/uploads\/2025\/07\/nhxh-j-0.6-1kv-fe180-e90-yangina-dayanikli-kablo-2.jpg","width":2000,"height":500,"caption":"(N)HXH-J 0.6\/1 kV FE180 E90 fire resistant cable \u2013 halogen-free LSZH insulated and sheathed, 180 min insulation & 90 min circuit integrity \u2013 ETK Kablo"},{"@type":"BreadcrumbList","@id":"https:\/\/www.etkkablo.com\/en\/product\/nhxh-j-061kv-fe180-e90-fire-resistant-cable\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.etkkablo.com\/en\/"},{"@type":"ListItem","position":2,"name":"\u00dcr\u00fcn Katalo\u011fu","item":"https:\/\/www.etkkablo.com\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"(N)HXH-J 0.6\/1kV FE180 E90 Fire Resistant Cable"}]},{"@type":"WebSite","@id":"https:\/\/www.etkkablo.com\/en\/#website","url":"https:\/\/www.etkkablo.com\/en\/","name":"ETK Kablo English","description":"ETK Kablo is a leading manufacturer of fiber optic, telecom, and data cables. Discover high-performance cable solutions for global communication networks.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.etkkablo.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/product\/2552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/media\/2553"}],"wp:attachment":[{"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/media?parent=2552"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/product_brand?post=2552"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/product_cat?post=2552"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.etkkablo.com\/en\/wp-json\/wp\/v2\/product_tag?post=2552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}