1 - Conductor | : | Electrolytic annealed solid copper (CCITT Yellow Book Vol. III-2-G.541 B article, IEC 28 and ASTM B 3). |
2 - Insulation | : | Color coded foam skin polyethylene cladded with solid polyethylene (BS 6234 Type 03 - ASTM D 1248). |
3 - Stranding | : | Star quads or pairs are assembled into 10 pairs units. Groups having 25, 50 or 100 pairs are stranded together. |
4 - Wrapping | : | A non-hygroscopic and dielectric polyester tape is applied on the cable core longitudinally or helically. |
5 - Messenger Wire | : | Galvanized steel messenger wire (ASTM A 475-66T). |
6 - Outer Jacket | : | Linear low-density or medium-density, UV resistant black polyethylene outer jacket (ASTM D 1248). |
Conductor Diameter | |||||||
---|---|---|---|---|---|---|---|
0.40 mm | 0.50 mm | 0.60 mm | 0.63 mm | 0.65 mm | 0.80 mm | 0.90 mm | |
Conductor Resistance Ω/km (20 °C) | |||||||
Maximum Average | 139,4 | 89,4 | 62,1 | 58 | 57 | 35 | 27,6 |
Maximum Individual | 146,6 | 93 | 64,6 | 60 | 58 | 37 | 28,8 |
Insulation Resistance MΩ/km (500 VDC) | >10000 | >10000 | >15000 | >15000 | >15000 | >15000 | >15000 |
Mutual Capacitance nF/km (800 Hz) | |||||||
Maximum Average | 50 | 50 | 45 | 45 | 45 | 45 | 45 |
Maximum Individual | 56 | 56 | 51 | 51 | 51 | 51 | 51 |
Capacitance Unbalance pF/500 m | |||||||
Between Pairs | |||||||
Maximum Average | 125 | 125 | 60 | 60 | 60 | 60 | 60 |
Maximum Individual | 350 | 350 | 325 | 325 | 325 | 325 | 325 |
Between Adjacent Quads | |||||||
Maximum Average | 125 | 125 | 60 | 60 | 60 | 60 | 60 |
Maximum Individual | 275 | 275 | 270 | 270 | 270 | 270 | 270 |
To Screen | |||||||
Maximum Average | 500 | 500 | 325 | 325 | 325 | 325 | 325 |
Maximum Individual | 2000 | 2000 | 1300 | 1300 | 1300 | 1300 | 1300 |
Dielectric Strength | |||||||
V (DC, 1 minute) | |||||||
Pair - Pair | 1400 | 1400 | 2000 | 2000 | 2000 | 2400 | 3000 |
Pair - Screen | 1400 | 1400 | 2000 | 2000 | 2000 | 2400 | 3000 |
KPD-P-A - PD-P-A (Quad) | ||||||||
---|---|---|---|---|---|---|---|---|
Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
3.131.4.5.1.0040.0.0002 | - | 2 | 0,4 | 4,2 | 4,8 | 40 | 1000/2000 | |
3.131.4.5.1.0040.0.0004 | - | 4 | 0,4 | 5 | 9,5 | 50 | 1000/2000 | |
3.131.4.5.1.0040.0.0006 | - | 6 | 0,4 | 6,2 | 14,3 | 62 | 1000/2000 | |
3.131.4.5.1.0040.0.0010 | - | 10 | 0,4 | 6,4 | 23,7 | 74 | 1000/2000 |
KPD-P-A - PD-P-A (Quad) | ||||||||
---|---|---|---|---|---|---|---|---|
Part Number | Number of Conductors | Pair Count | Conductor Diameter (mm) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Weight (kg/km) | Packing Lengths (m) | |
3.131.4.5.1.0050.0.0002 | - | 2 | 0,5 | 4,4 | 7,5 | 43 | 1000/2000 | |
3.131.4.5.1.0050.0.0004 | - | 4 | 0,5 | 5,6 | 14,9 | 79 | 1000/2000 | |
3.131.4.5.1.0050.0.0006 | - | 6 | 0,5 | 6,7 | 22,3 | 92 | 1000/2000 | |
3.131.4.5.1.0050.0.0010 | - | 10 | 0,5 | 6,9 | 37,1 | 117 | 1000/2000 |