JE-2Y(St)CH xDSL Telecom Cable

Product Code:

1 – Conductor : Electrolytic solid copper conductor.
2 – Insulation : Solid polyethylene insulation
3 – Stranding : Pair stranding, pairs are stranded into groups
4 – Wrapping : Polyester tape
5 – Screen : Tinned copper earthing wire, Al/PET tape, tinned copper braiding
6 – Outer Jacket : EN 50290-2-27. UV resistant halogen-free outer jacket. RAL 7035 (Grey)
Conductor
Diameter
Ω/km
Insulation Resistance
MΩxkm
(500 V DC)
Mutual Capacitance
nF/km
Capacitance
Unbalance
Dielectric Strength
V
Operating Voltage
V
Test Voltage
V
Capacitance Unbalance
pF/500m
Characteristic Impedance
Ω
146200056%210002501200200100±10
Smoke Density TestCorrosive Gas TestHalogen-free TestFlame Retardancy Test
IEC 61034-2
VDE 0482-1034-2
EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
IEC60754-1
VDE 0482-267-2-1
EN 50267-2-1
IEC 60332-1-2
VDE 0482-332-1-2
EN 60332-1-2
Bending RadiusTemperature Range
Operating
10xD mm-40°C~+70°C
Frequency
MHz
Insertion Loss
dB/100m (Max.)
Near-end Crosstalk (NEXT)
Loss dB (Min.)
Propagation Delay
5 n/m
1≤30≥55≤6
10≤100≥45≤5.7
16≤110≥40
20≤120≥38
30≤160≥35