H1Z2Z2-K Solar Cable

Product Code: H1Z2Z2-K

1 – Conductor:Stranded electrolytic tinned copper conductor (Class 5) (IEC 60228, EN 60228, DIN VDE 0295).
2 – Insulation:Cross-linked (XL) HFFR (EN 60811, EN 60216-1-2).
3 – Outer Jacket:Cross-linked (XL) HFFR outer jacket. RAL 9005 (Black) or RAL 3000 (Red)
Cross SectionConductor Resistance
Ω/km
(20 °C)
Operating Voltage
V DC
Test Voltage
V DC
(1 minute)
1.50 mm²13.70300/5001500
2.50 mm²8.21300/5001500
4.00 mm²5.09300/5001500
6.00 mm²3.39300/5001500
10.00 mm²1.95300/5001500
16.00 mm²1.24300/5001500
25.00 mm²0.795300/5001500
35.00 mm²0.565300/5001500
Smoke Density TestCorrosive Gas TestHalogen-free TestFlame Retardancy TestFlame Propagation Test
IEC 61034-2,
VDE 0482-1034-2,
BS EN 61034-2,
BS EN 61034-2
IEC 60754-2,
VDE 0482-754-2,
EN 60754-2,
BS EN 60754-2
IEC 60754-1,
VDE 0482-754-1,
EN 60754-1,
BS EN 60754-1
IEC 60332-1-2,
VDE 0482-332-1-2,
EN 60332-1-2,
BS EN 60332-1-2
IEC 60332-3-24,
VDE 0482-332-3-24,
EN 60332-3-24,
BS EN 60332-3-24
Bending RadiusTemperature Range
Operating
8xD mm-40°C ~ +90°C