LI2Y(St)Y-PiMF/TiMF Signal Control Cable

Product Code: LI2Y(St)Y-PiMF/TiMF

1 – Conductor:Stranded electrolytic copper conductor (Class 5) (IEC 60228, EN 60228, DIN VDE 0295)
2 – Insulation:Solid polyethylene (EN 50290-2-23, BS 6234 Type 03 – ASTM D 1248) (DIN 47100)
3 – Stranding:Screened pairs or triads are stranded in layers.
4 – Individual Wrapping:Polyester tape
5 – Individual Screen:Tinned copper earthing wire, Al/PET tape
6 – Wrapping:Polyester tape
7 – Screen:Tinned copper earthing wire, Al/PET tape
8 – Outer Jacket:UV resistant PVC outer jacket. RAL 7035 (Grey)
Cross
Section
Conductor Resistance
(20 °C)
Ω/km
Insulation
Resistance
(20 °C)
MΩ/km
Mutual Capacitance

nF/km
Operating
Voltage

V DC
Test Voltage

(@ 1 minute)
V DC
0.22 mm²85.050001102501200
0.25 mm²77.850001102501200
0.34 mm²56.050001102501200
0.50 mm²39.05000120300/5002000
0.75 mm²26.05000120300/5002000
1.00 mm²19.55000130300/5002000
1.50 mm²13.35000140300/5002000
2.50 mm²7.985000150300/5002000
Flame Retardancy Test
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0022.0.0002–20,22715,141100/500/1000
3.551.2.1.2.0022.0.0003–30,227,521,653100/500/1000
3.551.2.1.2.0022.0.0004–40,228,42869100/500/1000
3.551.2.1.2.0022.0.0005–50,229,234,581100/500/1000
3.551.2.1.2.0022.0.0006–60,221140,995100/500/1000
3.551.2.1.2.0022.0.0007–70,221147,4107100/500/1000
3.551.2.1.2.0022.0.0008–80,221153,8119100/500/1000
3.551.2.1.2.0022.0.0009–90,221360,3136100/500/1000
3.551.2.1.2.0022.0.0010–100,221366,7148100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0025.0.0002–20,257,416,244100/500/1000
3.551.2.1.2.0025.0.0003–30,257,923,257100/500/1000
3.551.2.1.2.0025.0.0004–40,258,830,274100/500/1000
3.551.2.1.2.0025.0.0005–50,259,737,187100/500/1000
3.551.2.1.2.0025.0.0006–60,251144,1103100/500/1000
3.551.2.1.2.0025.0.0007–70,251151,1115100/500/1000
3.551.2.1.2.0025.0.0008–80,251258,1129100/500/1000
3.551.2.1.2.0025.0.0009–90,251465,1148100/500/1000
3.551.2.1.2.0025.0.0010–100,251472,1162100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0034.0.0002–20,348,219,954100/500/1000
3.551.2.1.2.0034.0.0003–30,348,828,870100/500/1000
3.551.2.1.2.0034.0.0004–40,349,737,788100/500/1000
3.551.2.1.2.0034.0.0005–50,341146,5107100/500/1000
3.551.2.1.2.0034.0.0006–60,341255,4124100/500/1000
3.551.2.1.2.0034.0.0007–70,341264,3139100/500/1000
3.551.2.1.2.0034.0.0008–80,341373,1156100/500/1000
3.551.2.1.2.0034.0.0009–90,341682182100/500/1000
3.551.2.1.2.0034.0.0010–100,341690,9198100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0050.0.0002–20,59,532,374100/500/1000
3.551.2.1.2.0050.0.0003–30,5114697100/500/1000
3.551.2.1.2.0050.0.0004–40,51259,7124100/500/1000
3.551.2.1.2.0050.0.0005–50,51373,5146100/500/1000
3.551.2.1.2.0050.0.0006–60,51487,2173100/500/1000
3.551.2.1.2.0050.0.0007–70,514100,9194100/500/1000
3.551.2.1.2.0050.0.0008–80,515114,6218100/500/1000
3.551.2.1.2.0050.0.0009–90,518128,3253100/500/1000
3.551.2.1.2.0050.0.0010–100,518142,1271100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0075.0.0002–20,751141,290100/500/1000
3.551.2.1.2.0075.0.0003–30,751259,3118100/500/1000
3.551.2.1.2.0075.0.0004–40,751377,4153100/500/1000
3.551.2.1.2.0075.0.0005–50,751495,6182100/500/1000
3.551.2.1.2.0075.0.0006–60,7515113,7214100/500/1000
3.551.2.1.2.0075.0.0007–70,7515131,9241100/500/1000
3.551.2.1.2.0075.0.0008–80,7517150270100/500/1000
3.551.2.1.2.0075.0.0009–90,7520168,2314100/500/1000
3.551.2.1.2.0075.0.0010–100,7520186,3336100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0100.0.0002–211247,8103100/500/1000
3.551.2.1.2.0100.0.0003–311269,3136100/500/1000
3.551.2.1.2.0100.0.0004–411490,7174100/500/1000
3.551.2.1.2.0100.0.0005–5115112,2207100/500/1000
3.551.2.1.2.0100.0.0006–6116133,6245100/500/1000
3.551.2.1.2.0100.0.0007–7116155,1275100/500/1000
3.551.2.1.2.0100.0.0008–8118176,5310100/500/1000
3.551.2.1.2.0100.0.0009–9121198354100/500/1000
3.551.2.1.2.0100.0.0010–10121219,5386100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0150.0.0002–21,51266,3127100/500/1000
3.551.2.1.2.0150.0.0003–31,51397169100/500/1000
3.551.2.1.2.0150.0.0004–41,515127,7218100/500/1000
3.551.2.1.2.0150.0.0005–51,516158,5261100/500/1000
3.551.2.1.2.0150.0.0006–61,518189,2309100/500/1000
3.551.2.1.2.0150.0.0007–71,518219,9349100/500/1000
3.551.2.1.2.0150.0.0008–81,519250,6393100/500/1000
3.551.2.1.2.0150.0.0009–91,523281,3454100/500/1000
3.551.2.1.2.0150.0.0010–101,523312489100/500/1000
Part NumberConductor CountPair CountConductor Cross-section (mm²)Approx. Cable Diameter (mm)Copper Weight (kg/km)Approx. Weight (kg/km)Packing Lengths (m)
3.551.2.1.2.0250.0.0002–22,515100,8186100/500/1000
3.551.2.1.2.0250.0.0003–32,516148,7251100/500/1000
3.551.2.1.2.0250.0.0004–42,518196,7324100/500/1000
3.551.2.1.2.0250.0.0005–52,520244,6390100/500/1000
3.551.2.1.2.0250.0.0006–62,522292,6462100/500/1000
3.551.2.1.2.0250.0.0007–72,522340,5523100/500/1000
3.551.2.1.2.0250.0.0008–82,524388,4591100/500/1000
3.551.2.1.2.0250.0.0009–92,528503,8744100/500/1000
3.551.2.1.2.0250.0.0010–102,528484,3736100/500/1000
Bending RadiusTemperature Range
Operating
7.5xD mm-30°C ~ +70°C