Cat 6A F/FTP LSOH Ethernet Cable

Product Code:

1 – Conductor:Electrolytic solid copper conductor
2 – Insulation:Foamed polyethylene cladded with solid polyethylene
3 – Indv. Stranding:Insulations are stranded into pairs
4 – Indv. Screen:Al/PET tape
5 – Screen Wire:A tinned copper earthing wire between screened pairs
6 – Ovrl. Stranding:In layers
7 – Ovrl. Screen:Al/PET tape
8 – Outer Jacket:UV resistant halogen-free outer jacket
Conductor Resistance
Ω/km
(20 °C)
Insulation Resistance
MΩ/km
(20 °C)
Mutual Capacitance

nF/km
Resistance
Unbalance
Propagation
Velocity
Characteristic
Impedance
Ω
(1-500 MHz)
Operating Voltage
V DC
Test
Voltage
V
(DC. 1 minute)
Max. 945000Max. 56%2%78-80100 ±%51251200
ManufacturingSmoke Density TestFlame Retardancy TestCorrosive Gas TestHalogen-free Test
ANSI/TIA-568-C.2,
IEC-61156-5,
IEC-11801
IEC 61034-2,
VDE 0482-1034-2,
BS EN 61034-2
IEC 60332-1-2,
VDE 0482-332-1-2,
BS EN 60332-1-2
IEC 60754-2,
VDE 0482-267-2-3,
BS EN 50267-2-3
IEC 60754-1,
VDE 0482-267-2-1,
BS EN 50267-2-1
Part NumberPair CountConductor
Diameter
(AWG)
Approx.
Cable
Diameter
(mm)
Copper
Weight
(kg/km)
Approx.
Cable
Weight
(kg/km)
Packing
Lengths
(m)
3.46A10.12.5.0.0.3|0.A1Db.044237.220.154500/1000
Bending RadiusTemperature Range
Operating
8.0xD mm-20°C ~ +60°C
Frequency

MHz
Insertion Loss
dB/100m
(Max.)
Near-end
Crosstalk (NEXT)
dB
(Min.)
Power-sum Near-end
Crosstalk (PSNEXT)
dB
(Min.)
Equal-level Far-end
Crosstalk (ELFEXT)
dB/100m
(Min.)
Power-sum Equal Level Far-
end Crosstalk (PSELFEXT)
dB/100m
(Min.)
Return
Loss (RL)
dB
(Min.)
12.174.372.367.864.820
43.865.363.355.852.823
85.360.858.849.746.724.5
105.959.357.347.844.825
167.556.254.243.740.725
208.454.852.841.838.825
259.453.351.339.836.824.3
31.2510.551.949.937.934.923.6
62.51547.445.431.928.921.5
10019.144.342.327.824.820.1
20027.639.837.821.818.818
25031.138.336.319.816.817.3
30034.337.135.118.315.316.8
40040.135.333.315.812.815.9
50045.333.831.813.810.815.2