| 1 – Conductor | : | Electrolytic solid copper conductor |
| 2 – Insulation | : | Solid polyethylene insulation |
| 3 – Stranding | : | Insulations are stranded into pairs |
| 4 – Seperator | : | Pairs are stranded together with star shaped separator |
| 5 – Outer Jacket | : | UV resistant halogen-free outer jacket |
| Conductor Resistance Ω/km (20 °C) | Insulation Resistance MΩ/km (20 °C) | Mutual Capacitance nF/km | Resistance Unbalance | Propagation Velocity | Characteristic Impedance Ω (1-500 MHz) | Operating Voltage V DC | Test Voltage V (DC. 1 minute) |
|---|---|---|---|---|---|---|---|
| Max. 94 | 5000 | Max. 56 | %2 | %78-80 | 100 ±%5 | 125 | 1200 |
| Manufacturing | Smoke Density Test | Flame Retardancy Test | Corrosive Gas Test | Halogen-free Test |
|---|---|---|---|---|
| ANSI/TIA-568-C.2, IEC-61156-5, IEC-11801 | IEC 61034-2, VDE 0482-1034-2, BS EN 61034-2 | IEC 60332-1-2, VDE 0482-332-1-2, BS EN 60332-1-2 | IEC 60754-2, VDE 0482-267-2-3, BS EN 50267-2-3 | IEC 60754-1, VDE 0482-267-2-1, BS EN 50267-2-1 |
| Part Number | Pair Count | Conductor Diameter (AWG) | Approx. Cable Diameter (mm) | Copper Weight (kg/km) | Approx. Cable Weight (kg/km) | Packing Lengths (m) |
|---|---|---|---|---|---|---|
| 3.46A00.02.1.0.0.3|0.A1Db.04 | 4 | 23 | 6.0 | 18.9 | 44 | 305/500/1000 |
| Bending Radius | Temperature Range Operating |
|---|---|
| 8.0xD mm | -20°C ~ +60°C |
| Frequency MHz | Insertion Loss dB/100m (Max.) | Near-end Crosstalk (NEXT) dB (Min.) | Power-sum Near-end Crosstalk (PSNEXT) dB (Min.) | Equal-level Far-end Crosstalk (ELFEXT) dB/100m (Min.) | Power-sum Equal Level Far- end Crosstalk (PSELFEXT) dB/100m (Min.) | Return Loss (RL) dB (Min.) |
|---|---|---|---|---|---|---|
| 1 | 2.1 | 74.3 | 72.3 | 67.8 | 64.8 | 20 |
| 4 | 3.8 | 65.3 | 63.3 | 55.8 | 52.8 | 23 |
| 8 | 5.3 | 60.8 | 58.8 | 49.7 | 46.7 | 24.5 |
| 10 | 5.9 | 59.3 | 57.3 | 47.8 | 44.8 | 25 |
| 16 | 7.5 | 56.2 | 54.2 | 43.7 | 40.7 | 25 |
| 20 | 8.4 | 54.8 | 52.8 | 41.8 | 38.8 | 25 |
| 25 | 9.4 | 53.3 | 51.3 | 39.8 | 36.8 | 24.3 |
| 31.25 | 10.5 | 51.9 | 49.9 | 37.9 | 34.9 | 23.6 |
| 62.5 | 15 | 47.4 | 45.4 | 31.9 | 28.9 | 21.5 |
| 100 | 19.1 | 44.3 | 42.3 | 27.8 | 24.8 | 20.1 |
| 200 | 27.6 | 39.8 | 37.8 | 21.8 | 18.8 | 18 |
| 250 | 31.1 | 38.3 | 36.3 | 19.8 | 16.8 | 17.3 |
| 300 | 34.3 | 37.1 | 35.1 | 18.3 | 15.3 | 16.8 |
| 400 | 40.1 | 35.3 | 33.3 | 15.8 | 12.8 | 15.9 |
| 500 | 45.3 | 33.8 | 31.8 | 13.8 | 10.8 | 15.2 |
CAT 6A U/UTP LSOH Data Cable for High-Speed Structured Networking
ETK Kablo’s CAT 6A U/UTP LSOH Ethernet Cable is a high-speed, halogen-free data cable designed for 10 Gigabit Ethernet (10GBASE-T) applications in data centers, commercial buildings, and enterprise networks. It supports up to 500 MHz bandwidth, ensuring consistent transmission performance and minimal signal attenuation in structured network environments.
High-Speed Performance and Construction
Manufactured with AWG23 solid copper conductors and unshielded twisted pairs (U/UTP), the cable offers superior NEXT and return loss performance over extended distances. It delivers stable and interference-free connectivity for VoIP, video conferencing, cloud applications, and data streaming. The CAT 6A design allows seamless operation of 10G Ethernet networks while maintaining backward compatibility with CAT 6 and CAT 5e systems.
Fire Safety and Compliance
The LSOH (Low Smoke Zero Halogen) outer sheath reduces smoke and toxic gas emissions in case of fire, ensuring safety in offices, hospitals, schools, airports, and public buildings. This cable meets international standards such as ISO/IEC 11801, EN 50173, and IEC 60332-1, and can be supplied with CPR-rated (Cca or Dca) classification upon request.
Applications and Installation
Designed for horizontal cabling and patch panel connections, CAT 6A U/UTP LSOH is suitable for fixed installations in structured cabling systems. It performs optimally in IT rooms, backbone routes, server racks, and network distribution panels, supporting next-generation data transmission up to 10 Gbps with long-term stability and reliability.
Comparison of ETK Kablo’s Structured Cabling Products
| Cable Type | Bandwidth | Max Speed | Shielding | Sheath Type | Typical Application |
|---|---|---|---|---|---|
| CAT 5e U/UTP PVC | 100 MHz | 1 Gbps | Unshielded (U/UTP) | PVC | Small office and residential Ethernet networks |
| CAT 6 U/UTP LSOH | 250 MHz | 1 Gbps | Unshielded (U/UTP) | LSOH | Commercial buildings and enterprise LANs |
| CAT 6A U/UTP LSOH | 500 MHz | 10 Gbps | Unshielded (U/UTP) | LSOH | Data centers, backbone cabling, enterprise networks |
| CAT 7 S/FTP PE | 600–1000 MHz | 10+ Gbps | Foil and braid shielded (S/FTP) | PE (Outdoor) | High-interference and outdoor data transmission |
Why Choose ETK Kablo’s CAT 6A U/UTP LSOH Cable?
Choose ETK Kablo’s CAT 6A U/UTP LSOH Ethernet Cable — the 10G-ready, halogen-free data cable engineered for maximum performance, fire safety, and network longevity in structured cabling systems worldwide.
Frequently Asked Questions about CAT 6A U/UTP LSOH Data Cable
What does CAT6 U/UTP mean?
CAT6 U/UTP stands for Category 6 Unshielded Twisted Pair cable. The “U/UTP” designation indicates that the cable has no overall or individual shielding around the twisted pairs. It is designed for Gigabit Ethernet applications up to 250 MHz and provides excellent data transmission performance in low-interference environments such as offices and residential networks.
What is CAT6A U/FTP?
CAT6A U/FTP (Unshielded Foiled Twisted Pair) is a 10 Gigabit Ethernet cable where each pair of conductors is individually foil-shielded to reduce crosstalk and electromagnetic interference (EMI). Compared to U/UTP, U/FTP offers improved noise immunity, making it suitable for high-density or electrically noisy installations.
What is a U/UTP cable?
A U/UTP cable (Unshielded / Unshielded Twisted Pair) is a type of Ethernet cable that contains unshielded twisted pairs without any foil or braid. It is lightweight, flexible, and easy to install. ETK Kablo’s CAT 6A U/UTP LSOH version combines this simplicity with LSOH (Low Smoke Zero Halogen) safety for use in data centers, offices, and public buildings.
Is F/UTP better than U/UTP?
F/UTP (Foiled Twisted Pair) cables provide better protection against electromagnetic interference than U/UTP because they include an overall aluminum foil shield. However, U/UTP cables like ETK Kablo’s CAT 6A U/UTP LSOH are often preferred for indoor environments due to their ease of installation, flexibility, and lower cost when EMI levels are moderate.
Which is better, STP or UTP?
STP (Shielded Twisted Pair) cables offer stronger noise immunity and are better suited for environments with high electromagnetic interference such as industrial areas or near heavy machinery. UTP (Unshielded Twisted Pair) cables, like CAT 6A U/UTP LSOH, are typically used in structured indoor networks where EMI is minimal, providing easier handling and lower installation costs.